Adaptive Programming examples for crane control
297
Adaptive Programming examples for crane control
Chapter overview
This chapter includes examples of Adaptive Programming (AP) for Crane control
program (+N697).
For more information on Adaptive Programming, see
on page
Application Guide for Adaptive Program
(3AFE64527274 [English]). For information on DriveAP (a Windows-based tool for
Adaptive Programming), see
DriveAP User’s Manual
(3AFE64540998 [English]).
Note:
If you use and/or change the AP blocks used in the Crane control program
made by ABB, you are responsible for the software and the application.
Main contactor control logic
Using the Adaptive Programming (AP), you can create a main contactor control logic
for the 3-phase power supply of the ACS800 drive. With the help of the main
contactor control logic, the power supply of the drive is disabled when the crane is
not used (the standby energy-efficiency mode).
For this, you must have the +24 V DC external auxiliary voltage supplied to the
RMIO board (see
External 24 V supply of RMIO board
). You can use a
RMIO or RDIO relay output for controlling the main contactor, and you can close the
main contactor with a command through a dedicated digital input of RMIO or RDIO.
For more information, see the
Application Guide for Adaptive Program
(3AFE64527274 [English]) and
DriveAP User’s Manual
(3AFE64540998 [English]).
Содержание ACS 800 Series
Страница 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Страница 4: ......
Страница 26: ...Start up and control through the I O interface 26 ...
Страница 36: ...Quick start up guide 36 ...
Страница 52: ...Control panel 52 ...
Страница 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Страница 126: ...Program features 126 The figures below show speed limits according to different load conditions ...
Страница 128: ...Program features 128 ...
Страница 150: ...Application macros control location EXT1 EXT2 150 ...
Страница 228: ...Actual signals and parameters 228 ...
Страница 299: ...Adaptive Programming examples for crane control 299 ...
Страница 305: ...Adaptive Programming examples for crane control 305 ...
Страница 312: ...Adaptive Programming examples for crane control 312 The following figures show the previous example enlarged ...
Страница 314: ...Adaptive Programming examples for crane control 314 The following figures show the previous example enlarged ...
Страница 318: ...Analogue Extension Module 318 ...
Страница 332: ...Additional data actual signals and parameters 332 ...
Страница 333: ...DriveWindow 333 DriveWindow DriveWindow connected to the ACS800 RMIO RDCO board and channel CH3 ...
Страница 334: ...DriveWindow 334 ...
Страница 335: ...Control block diagrams 335 Control block diagrams ...
Страница 336: ...Control block diagrams 336 ...
Страница 337: ...Control block diagrams 337 ...
Страница 338: ...Control block diagrams 338 ...
Страница 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...