Fieldbus control
256
Fieldbus references in a Master/Follower configuration
When the ABB Drives communication profile is active, the fieldbus interface uses the
following references in the Master drive:
• When the Master is in control location EXT1 (stand-alone, speed-controlled), the
fieldbus interface uses REF1 for the speed reference.
• When the Master is in control location EXT2 (Master/Follower, either speed-
controlled or torque-controlled depending on the selection of Par.
TORQUE
SELECTOR), the fieldbus interface uses REF2 for the speed or torque reference.
When the ABB Drives communication profile is active, the fieldbus interface uses the
following references in the Follower drives:
• When Follower n is in control location EXT1 (stand-alone, speed-controlled), the
fieldbus interface uses REF1 for the speed reference.
Note
: For the fieldbus interface to work in follower drives in EXT1, Par.
MASTER LINK MODE must be set to value NOT IN USE in the follower drives.
Ensure this either through the fieldbus (parameter writing) or DriveAP's Write
block.
• When Follower n is in control location EXT2 (Master/Follower, either speed-
controlled or torque-controlled depending on the selection of Par.
TORQUE
SELECTOR), the fieldbus interface cannot control the references because they
come through the M/F link (CH).
The figure below illustrates the use of fieldbus references in a Master/Follower
configuration.
Follower n
Master
CH2
EXT 1
Stand-alone mode
EXT1 STRT/STP/DIR
EXT REF1 SELECT
EXT 2
Master/Follower
EXT2 STRT/STP/DIR
EXT REF2 SELECT
EXT 1
Stand-alone mode
EXT1 STRT/STP/DIR
EXT REF1 SELECT
EXT 2
Master/Follower
EXT2 STRT/STP/DIR
EXT REF2 SELECT
Note
: In follower drives in EXT1,
Par.
must have value NOT IN
USE for the fieldbus interface to
work.
Содержание ACS 800 Series
Страница 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Страница 4: ......
Страница 26: ...Start up and control through the I O interface 26 ...
Страница 36: ...Quick start up guide 36 ...
Страница 52: ...Control panel 52 ...
Страница 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Страница 126: ...Program features 126 The figures below show speed limits according to different load conditions ...
Страница 128: ...Program features 128 ...
Страница 150: ...Application macros control location EXT1 EXT2 150 ...
Страница 228: ...Actual signals and parameters 228 ...
Страница 299: ...Adaptive Programming examples for crane control 299 ...
Страница 305: ...Adaptive Programming examples for crane control 305 ...
Страница 312: ...Adaptive Programming examples for crane control 312 The following figures show the previous example enlarged ...
Страница 314: ...Adaptive Programming examples for crane control 314 The following figures show the previous example enlarged ...
Страница 318: ...Analogue Extension Module 318 ...
Страница 332: ...Additional data actual signals and parameters 332 ...
Страница 333: ...DriveWindow 333 DriveWindow DriveWindow connected to the ACS800 RMIO RDCO board and channel CH3 ...
Страница 334: ...DriveWindow 334 ...
Страница 335: ...Control block diagrams 335 Control block diagrams ...
Страница 336: ...Control block diagrams 336 ...
Страница 337: ...Control block diagrams 337 ...
Страница 338: ...Control block diagrams 338 ...
Страница 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...