Actual signals and parameters
157
Parameters
Index
Name/Selection
Description
FbEq
10 START/STOP/DIR
The sources for external start, stop and direction control
10.01
EXT1 STRT/STP/DIR Defines the connections and the source of the Start, Stop and Direction
commands for external control location 1 (EXT1).
Note
: In M/F configuration, EXT2 should be used for M/F mode and EXT1 for
stand-alone mode.
NOT SEL
No Start, Stop and Direction command source.
1
DI1 F, DI2 R
Start, Stop and Direction commands through digital inputs DI1 and DI2.
Note:
Parameter
REF DIRECTION must be REQUEST.
2
DI3 F, DI4R
Start, Stop and Direction commands through digital inputs DI3 and DI4.
See selection DI1 F, DI2 R.
3
DI5 F, DI6 R
Start, Stop and Direction commands through digital inputs DI5 and DI6.
See selection DI1 F, DI2 R.
4
KEYPAD
Control panel. To control the direction, parameter
be REQUEST.
5
COMM.CW
bit 3 on page
. 6
PARAM 10.04
Source selected with parameter
EXT1 STRT PTR. This selection can be
used for joystick controls when the joystick reference is used for deciding the
direction.
7
10.02
EXT2 STRT/STP/DIR Defines the connections and the source of the Start, Stop and Direction
commands for external control location 2 (EXT2).
Note
: In M/F configuration, EXT2 should be used for M/F mode and EXT1 for
stand-alone mode.
NOT SEL
See parameter
EXT1 STRT/STP/DIR.
1
DI1 F, DI2 R
See parameter
EXT1 STRT/STP/DIR.
2
DI3 F, DI4R
See parameter
EXT1 STRT/STP/DIR.
3
DI5 F, DI6 R
See parameter
EXT1 STRT/STP/DIR.
4
KEYPAD
See parameter
EXT1 STRT/STP/DIR.
5
COMM.CW
See parameter
EXT1 STRT/STP/DIR.
6
PARAM 10.05
Source selected with
EXT2 STRT PTR.This selection can be used for
joystick controls when the joystick reference is used for deciding the direction.
7
10.03
REF DIRECTION
Enables the control of rotation direction of the motor, or fixes the direction.
FORWARD
Fixed to forward
1
REVERSE
Fixed to reverse
2
REQUEST
Direction of rotation control allowed
3
DI1
DI2
Operation
0
0
Stop
1
0
Start forward
0
1
Start reverse
1
1
Stop
Содержание ACS 800 Series
Страница 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Страница 4: ......
Страница 26: ...Start up and control through the I O interface 26 ...
Страница 36: ...Quick start up guide 36 ...
Страница 52: ...Control panel 52 ...
Страница 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Страница 126: ...Program features 126 The figures below show speed limits according to different load conditions ...
Страница 128: ...Program features 128 ...
Страница 150: ...Application macros control location EXT1 EXT2 150 ...
Страница 228: ...Actual signals and parameters 228 ...
Страница 299: ...Adaptive Programming examples for crane control 299 ...
Страница 305: ...Adaptive Programming examples for crane control 305 ...
Страница 312: ...Adaptive Programming examples for crane control 312 The following figures show the previous example enlarged ...
Страница 314: ...Adaptive Programming examples for crane control 314 The following figures show the previous example enlarged ...
Страница 318: ...Analogue Extension Module 318 ...
Страница 332: ...Additional data actual signals and parameters 332 ...
Страница 333: ...DriveWindow 333 DriveWindow DriveWindow connected to the ACS800 RMIO RDCO board and channel CH3 ...
Страница 334: ...DriveWindow 334 ...
Страница 335: ...Control block diagrams 335 Control block diagrams ...
Страница 336: ...Control block diagrams 336 ...
Страница 337: ...Control block diagrams 337 ...
Страница 338: ...Control block diagrams 338 ...
Страница 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...