156
19.4.3. Oil level in swing gear
P
RECAUTION WITH OIL AT HIGH TEMPERATURE
After the machine worked, oil is at high temperature, so
wait for temperature cool down before operate.
What prepare:
•
a pan to collect drained oil.
1. Put a container (pan) under the reduction unit.
2. Check the oil level with the lipstick.
3. If the oil level is low, add it through the filling
hole.
4. Clean the lipstick and check the oil level
again.
19.4.4. Cleaning water separator filter
The water separator filter is installed in the fuel pipeline.
If the ring (A) of the water separator is at the
bottom of case there is no water.
If the ring (A) is floating (B), there is water up to
the bottom of the ring, so drain the water as
follows.
1. Close the tap (C).
2. Unfasten the ring (D), then remove the case
and throw out the water inside.
3. Set the case in position then tighten the ring
(D) to install it.
4. St the tap (C) in open position.
A
B
C
D