1.4.2
Digital Input/Output Modules
The digital input module receives digital signals and converts them into internal data in the
safety control unit, or converts internal data and outputs digital signals.
n
Types of Digital Input/Output Modules
The following types of digital input/output modules are available in ProSafe-RS:
•
SDV144 : Non-voltage contact input, 16 channels, module isolation
•
SDV521 : 24 V DC output, 4 channels, module isolation
•
SDV526 : 100-120 V AC output, 4 channels, module isolation
•
SDV531 : 24 V DC output, 8 channels, module isolation
There is a different behavior between SDV531-S13 and SDV531-S23/-S33 as follows
when a short circuit occurs on the field side:
•
SDV531-S13
When short-circuit occurs on the field side, the Output Shutoff Switch is activated and
the output of all channels on the module becomes OFF. When the short-circuit error
is resolved, the outputs can be recovered by starting the output module from the SCS
Status Management Window and performing the Output Enable Operation. Then the
recovered output channels will output the application logic values. Without performing
the Output Enable Operation, all the outputs will be kept OFF.
•
SDV531-S23/-S33
When short-circuit occurs on the field side, the output of output channel correspond-
ing to that field device becomes OFF. When the short-circuit error is resolved, the
output channel can be recovered by performing the Output Enable Operation. Recov-
ered channel will output the application logic values. Without performing the Output
Enable Operation, this channel will output the fail-safe value.
•
SDV531-L : 24 V DC output, 8 channels, module isolation, long distance type
•
SDV53A : 48 V DC output, 8 channels, module isolation
•
SDV541 : 24 V DC output, 16 channels, module isolation
n
External View of Digital Input/Output Modules
The connections with the digital I/O modules vary with the types of adapters. Pressure clamp
terminals, terminal boards (with signal cable interface adapter) and MIL cables are used for
the connections. The following figure shows the external view of the SDV144, SDV541, and
SDV531. Since SDV521, SDV526 and SDV53A have a built-in signal cable interface adapter,
they can be connected only through the terminal board.