6-5
IM DL35O-03EN
Specifications
1
2
3
4
5
6
App
Index
Analysis
Item
Specifications
Cursor
T-Y waveform: Horizontal, Vertical, H&V, Marker, Degree
X-Y waveform: Horizontal, Vertical, H&V, Marker
FFT waveform: Marker, Peak
Automated measurement of waveform parameters
Measurement items
Analog waveform, Math
PP, Amp, Max, Min, High, Low, Avg, Mid, Rms, Sdev, +Over, −Over,
Rise, Fall, Freq, Period, +Width, −Width, Duty, Pulse, Burst1, Burst2, Avg.Freq,
AvgPeriod, Int1TY, Int2TY, Int1XY, Int2XY, Delay
One-cycle mode available
Logic waveform
Freq, Period, Pulse, Duty, Avg.Freq, Delay
Statistical processing
Statistics items: Max, Min, Avg, Sdv, Cnt
Maximum number of cycles: 10000
Maximum measuring range: No limit for data in memory Up to 100 Mpoints for SD
recording waveforms.
Normal statistical processing
Statistical processing is performed while waveforms are acquired.
History statistical processing
Automatically measures the waveform parameters for each history waveform and performs
statistical processing on the parameters.
Cyclic statistical processing
Automatically measures the waveform parameters once per cycle and performs statistical
processing on the parameters.
Waveform computation
Operators: +, –, ×, ÷, binarization, shift, frequency, period, moving average (10 points), RMS
Computation length: 2 Mpoint max. (when using one waveform)
FFT
Type: LS, RS, PS, PSD
Time window: Hanning, Hamming, FlatTop, Rectangle
Average: Time axis, frequency axis
Computed points: 1 k, 2 k, 5 k, 10 k, 20 k, 50 k, or 100 k
GO/NO-GO determination
Performs a selected operation according to the determination condition on the acquired
waveform
Zone determination
Maximum number of determination zones: 6, maximum number of source waveforms: 8,
determined based on AND or OR conditions
Parameter determination
Determination performed on the combination of up to eight parameters (waveform
parameters or harmonic analysis results)
Operation after determination
Screen capture data saving, waveform data saving, buzzer notification, mail transmission
Harmonic analysis
Number of simultaneous analysis Line 8 channels, power 1 system
Fundamental wave
50 Hz, 60 Hz, auto setting
FFT points
2048 points
Harmonics analyzed
Fundamental to 40th
Window span
10 periods (50 Hz), 12 periods (60 Hz), 8 periods (auto)
Harmonic analysis types
Harmonic rms, percentage content, phase angle, distortion (IEC, CSA), total rms value
Power analysis
Select single-phase, two-wire (1P2W); single-phase, three-wire (1P3W); or three-phase,
three-wire (3P3W).
Analysis result display
Select Line 8 channels or power 1 system.
Display format: List or bar graph
Analysis result recording
All analysis results can be recorded to a medium.
Data format: CSV
6.3 Scope Mode Features