5-6
IM DL350-03EN
Setup Errors (800 to 899)
Code
Message
Chapter or
Section
800
Illegal date-time.
Set the correct date and time.
–
801
Cannot set these file name.
- Over 32 characters.
- Contains character which are not allowed.
- Inhibit MS-DOS file name.
Enter an other file name.
6.3
1
802
Cannot set while recording.
3.1,
1
3.2
1
804
Cannot change settings during GO/NO-GO.
Stop the GO/NO-GO (Stop the Acquire) .
Chapter 13
1
806
Cannot be changed when trigger A is not X.
Set the state of the channel corresponding to
condition A to 'X'.
4.7
1
to 4.12
1
808
Cannot change when Channel Display is OFF or Math settings are invalid.
Set the channel display ON or make appropriate Math settings.
Chapter 2,
1
Chapter 9
1
809
Cannot change when External Clock is active.
3.1,
1
3.2
1
814
Cannot change settings while SD Card recording.
Stop SD recording.
–
815
Cannot change settings during Action mode.
Stop the Action.
3.1,
1
3.2
1
816
Cannot set the channels which do not have modules installed.
Chapter 2,
1
5.6
2
817
Cannot Set or Execute.
–
818
If the trigger mode is set to Single or OnStart, the acquisition mode cannot be set to Average.
3.1
1
819
If the acquisition mode is Average, the trigger mode cannot be set to Single or OnStart.
4.1
1
820
The acquisition mode cannot be set in the current record length.
–
822
Cannot be configured or executed during the search operation.
Chapter 16
1
824
The record cannot be selected.
17.1
1
825
History record does not exist.
17.1
1
826
Cannot be configured or executed while computation is in progress.
Aborted when history display mode is set to One.
17.1
1
827
Cannot be configured or executed while updating the history all display.
Aborted when history display mode is set to One.
17.1
1
829
Zones cannot be edited in the following cases:
* When the main window is not displayed.
* When the relevant waveform is not displayed.
13.1
1
830
The zone waveform does not exist.
13.1
1
831
The zone is being edited.
To perform other operations, exit zone editing.
13.1
1
832
Zones determination is not possible in the following cases:
* When the main window is not displayed.
* When the relevant waveform is not displayed.
* When the zone waveform does not exist.
Chapter 2,
1
10.1,
1
11.2,
1
14.2,
1
15.2
1
833
Processing statistics.
To perform other operations, abort the statistical processing.
8.2
1
834
There are no channels to be analyzed,
or you specified a channel that can not be set.
–
835
Cannot be set when the acquisition mode is set to average.
3.1
1
836
Cannot be changed when VScale is SPAN.
2.2
1
837
Cannot be set during SD Card recording.
–
840
Cannot be set to a range of 20 sec/div to 3 day/div during roll display.
3.1,
1
3.2
1
841
Cannot be set because there are too many display channels at the current record length.
Shorten the record length.
3.1
1
845
Cannot change the History parameter when accumulate is ON.
Turn OFF accumulate first.
5.3
1
847
Cannot set On this module.
–
848
Settings can not be entered for channels on which no strain module is mounted.
–
849
Setting error.
–
5.2 Messages and Corrective Actions
1 User’s Manual, IM DL350-02EN
2 Features Guide, IM DL350-01EN