2-55
IM 701450-51E
CAN Bus Signal Analysis Function
2
:TRIGger:CAN:DATA?
Function
Queries all settings related to the Data Field in
the trigger conditions.
Syntax
:TRIGger:CAN:DATA?
Example
:TRIGGER:CAN:DATA? -> :TRIGGER:CAN:
DATA:MODE 1;DLC 8;
PATTERN1 “XXXXXXXX”;
PATTERN2 “XXXX0000”;
PATTERN3 “XXXXXXXX”;
PATTERN4 “XXXXXXXX”;
PATTERN5 “XXXXXXXX”;
PATTERN6 “XXXXXXXX”;
PATTERN7 “XXXXXXXX”;
PATTERN8 “11111111”;CONDITION TRUE
:TRIGger:CAN:DATA:CONDition
Function
Sets the Data Field condition (True/False/
Greater/Less) in the trigger conditions or
queries the current setting.
Syntax
:TRIGger:CAN:DATA:CONDition
{TRUE|FALSe|GREater|LESS}
:TRIGger:CAN:DATA:CONDition?
Example
:TRIGGER:CAN:DATA:CONDITION FALSE
:TRIGGER:CAN:DATA:CONDITION? ->
:TRIGGER:CAN:DATA:CONDITION FALSE
:TRIGger:CAN:DATA:DLC
Function
Sets the number of valid bytes (DLC) of the
Data Field in the trigger conditions or queries
the current setting.
Syntax
:TRIGger:CAN:DATA:DLC {<NRf>}
:TRIGger:CAN:DATA:DLC?
<NRf>=1 to 8
Example
:TRIGGER:CAN:DATA:DLC 6
:TRIGGER:CAN:DATA:DLC? ->
:TRIGGER:CAN:DATA:DLC 6
:TRIGger:CAN:DATA:HEXa<x>
Function
Sets each byte of the Data Field patterns in the
trigger conditions in hexadecimal.
Syntax
:TRIGger:CAN:DATA:HEXa<x>
{<String>}
<x>=1 to 8
Example
:TRIGGER:CAN:DATA:HEXA1 “A3”
:TRIGger:CAN:DATA:MODE
Function
Sets whether trigger activates on the Data Field
in the trigger conditions or queries the current
setting.
Syntax
:TRIGger:CAN:DATA:MODE {<Boolean>}
:TRIGger:CAN:DATA:MODE?
Example
:TRIGGER:CAN:DATA:MODE 1
:TRIGGER:CAN:DATA:MODE? ->
:TRIGGER:CAN:DATA:MODE 1
:TRIGger:CAN:DATA:PATTern<x>
Function
Sets the Data Field pattern in the trigger
conditions in binary or queries the current
setting.
Syntax
:TRIGger:CAN:DATA:PATTern<x>
{<String>}
:TRIGger:CAN:DATA:PATTern<x>?
<x>=1 to 8
Example
:TRIGGER:CAN:DATA:
PATTERN1 “10X10X10”
:TRIGGER:CAN:DATA:PATTERN1? ->
:TRIGGER:CAN:DATA:
PATTERN1 “10X10X10”
:TRIGger:CAN:EFRame
Function
Sets whether trigger activates on the Error
Frame in the trigger conditions or queries the
current setting.
Syntax
:TRIGger:CAN:EFRame {<Boolean>}
:TRIGger:CAN:EFRame?
Example
:TRIGGER:CAN:EFRAME 1
:TRIGGER:CAN:EFRAME? ->
:TRIGGER:CAN:EFRAME 1
:TRIGger:CAN:IDENtifier?
Function
Queries all settings related to the Identifier in
the trigger conditions.
Syntax
:TRIGger:CAN:IDENtifier?
Example
:TRIGGER:CAN:IDENTIFIER? ->
:TRIGGER:CAN:IDENTIFIER:MODE 1;
CONDITION FALSE;ID1:MODE 1;
PATTERN “11111101100”;:TRIGGER:CAN:
IDENTIFIER:ID2:MODE 0;
PATTERN “XXXXXXXXXXX”;:TRIGGER:CAN:
IDENTIFIER:ID3:MODE 0;
PATTERN “XXXXXXXXXXX”;:TRIGGER:CAN:
IDENTIFIER:ID4:MODE 0;
PATTERN “XXXXXXXXXXX”
:TRIGger:CAN:IDENtifier:CONDition
Function
Sets the Identifier condition (True/False) in the
trigger conditions or queries the current setting.
Syntax
:TRIGger:CAN:IDENtifier:CONDition
{TRUE|FALSe}
:TRIGger:CAN:IDENtifier:CONDition?
Example
:TRIGGER:CAN:IDENTIFIER:
CONDITION FALSE
:TRIGGER:CAN:IDENTIFIER:CONDITION?
-> :TRIGGER:CAN:IDENTIFIER:
CONDITION FALSE
2.9 Communication Commands