2-51
IM 701450-51E
CAN Bus Signal Analysis Function
2
• CAN Cursor Group
Commands in the CAN CURSor group can be used to set and query the cursor of the CAN Bus signal analysis
function in the same fashion as the CURSOR key on the front panel.
:CURSor
:
TY
:
CAN
:
BRATe
<Space>
<Space>
<NRf>
?
?
?
JUMP
<Space>
ACK
CONTrol
CRC
DATA
IDENtifier
SOF
TYPE
<Space>
OFF
HORizontal
VERTical
MARKer
DEGRee
CAN
POSition
<x>
<NRf>
?
;
;
:CURSor:TY:CAN:POSition<x>
Function
Sets the CAN Cursor position or queries the
current setting.
Syntax
:CURSor:TY:CAN:POSition<x> {<NRf>}
:CURSor:TY:CAN:POSition<x>?
<x>=1, 2
<NRf>=–5 to 5 (10 div/displayed record length
steps)
Example
:CURSOR:TY:CAN:POSITION1 4
:CURSOR:TY:CAN:POSITION1? ->
:CURSOR:TY:CAN:POSITION1 -4.0000000
:CURSor:TY:TYPE
Function
Sets the cursor type of the T-Y display or
queries the current setting.
Syntax
:CURSor:TY:TYPE {OFF|HORizontal|
VERTical|MARKer|DEGRee|CAN}
:CURSor:TY:TYPE?
Example
:CURSOR:TY:TYPE CAN
:CURSOR:TY:TYPE? ->
:CURSOR:TY:TYPE CAN
2.9 Communication Commands
:CURSor:TY:CAN?
Function
Queries all settings related to the CAN Cursor.
Syntax
:CURSor:TY:CAN?
Example
:CURSOR:TY:CAN? -> :CURSOR:TY:CAN:
BRATE 500.000E+03;
POSITION1 -4.0000000;
POSITION2 -3.9980000
:CURSor:TY:CAN:BRATe
Function
Sets the bit rate (data transfer rate) of the CAN
Cursor or queries the current setting.
Syntax
:CURSor:TY:CAN:BRATe {<NRf>}
:CURSor:TY:CAN:BRATe?
<NRf>=10000 to 1000000 (except, the
resolution is the reciprocal of 0.5
µ
s)
Example
:CURSOR:TY:CAN:BRATE 500000
:CURSOR:TY:CAN:BRATE? ->
:CURSOR:TY:CAN:BRATE 500.000E+03
:CURSor:TY:CAN:JUMP
Function
Executes the jumping of the CAN Cursor to a
specified field.
Syntax
:CURSor:TY:CAN:JUMP {SOF|
IDENtifier|CONTrol|DATA|CRC|ACK}
Example
:CURSOR:TY:CAN:JUMP SOF