2-7
IM 701450-51E
CAN Bus Signal Analysis Function
2
Setting the Sample Point
11.
Use
jog shuttle & SELECT
to set the sample point in the range of 18.8 to 90.6
(Sample Point box).
Selecting Vdiff
12.
Use
jog shuttle & SELECT
to set Vdiff to CAN_L–CAN_H or CAN_H–CAN_L
(Vdiff box).
Set the sample point in the range of
18.8 to 90.6%
Select Vdiff.
Selecting the Message Format
13.
Use
jog shuttle & SELECT
to set the message format to Std or Ext (Message
Format box). The Identifier setting format changes to the selected format.
The Identifier
setting format
changes to Std
(standard) format.
T
he Identifier
setting format
changes to Ext
(extended) format.
When Ext is selected
When Std is selected
Selecting the Pattern Format
14.
Use
jog shuttle & SELECT
to set the pattern format to Hex or Bin (Pattern
Format box). The Identifier and Data Field setting format changes to the
selected format.
The Identifier and Data
Field setting format
changes to the Hex
(hexadecimal) format.
The Identifier and Data
Field setting format
changes to the Bin
(binary) format.
When Hex is selected
When Bin is selected