1-42
IM 701450-51E
:SEARch:I2C:ANALyze:SETup:CLOCk:
LEVel
Function
Sets the clock channel level of the analysis
conditions or queries the current setting.
Syntax
:SEARch:I2C:ANALyze:SETup:CLOCk:
LEVel {<Voltage>}
:SEARch:I2C:ANALyze:SETup:CLOCk:
LEVel?
<Voltage>=8 divisions within the screen (0.01
division steps).
Example
:SEARCH:I2C:ANALYZE:SETUP:CLOCK:
LEVEL 1V
:SEARCH:I2C:ANALYZE:SETUP:CLOCK:
LEVEL? -> :SEARCH:I2C:ANALYZE:
SETUP:CLOCK:LEVEL 1.000E+00
Description
If you are setting a clock channel to which a
current probe is connected, set and query using
<Current>.
:SEARch:I2C:ANALyze:SETup:CLOCk:
SOURce
Function
Sets the clock channel source waveform of the
analysis conditions or queries the current
setting.
Syntax
:SEARch:I2C:ANALyze:SETup:CLOCk:
SOURce {<NRf>}
:SEARch:I2C:ANALyze:SETup:CLOCk:
SOURce?
<NRf>=1, 3
Example
:SEARCH:I2C:ANALYZE:SETUP:CLOCK:
SOURCE 1
:SEARCH:I2C:ANALYZE:SETUP:CLOCK:
SOURCE? -> :SEARCH:I2C:ANALYZE:
SETUP:CLOCK:SOURCE 1
:SEARch:I2C:ANALyze:SETup:DATA?
Function
Queries all settings related to the data channel
of the analysis conditions.
Syntax
:SEARch:I2C:ANALyze:SETup:DATA?
Example
:SEARCH:I2C:ANALYZE:SETUP:DATA? ->
:SEARCH:I2C:ANALYZE:SETUP:DATA:
SOURCE 2;LEVEL 1.000E+00,0.000E+00
1.8 Communication Commands
:SEARch:I2C:ANALyze:SETup:DATA:LEVel
Function
Sets the threshold level of the data channel of
the analysis conditions or queries the current
setting.
Syntax
:SEARch:I2C:ANALyze:SETup:DATA:
LEVel {<Voltage>,<Voltage>}
:SEARch:I2C:ANALyze:SETup:DATA:
LEVel?
<Voltage>=8 divisions within the screen (0.01
division steps).
Example
:SEARCH:I2C:ANALYZE:SETUP:DATA:
LEVEL 1V,0V
:SEARCH:I2C:ANALYZE:SETUP:DATA:
LEVEL? -> :SEARCH:I2C:ANALYZE:
SETUP:DATA:
LEVEL 1.000E+00,0.000E+00
Description
If you are setting a data channel to which a
current probe is connected, set and query using
<Current>.
:SEARch:I2C:ANALyze:SETup:DATA:
SOURce
Function
Sets the data channel source waveform of the
analysis conditions or queries the current
setting.
Syntax
:SEARch:I2C:ANALyze:SETup:DATA:
SOURce {<NRf>}
:SEARch:I2C:ANALyze:SETup:DATA:
SOURce?
<NRf>=2, 4
Example
:SEARCH:I2C:ANALYZE:SETUP:DATA:
SOURCE 2
:SEARCH:I2C:ANALYZE:SETUP:DATA:
SOURCE? -> :SEARCH:I2C:ANALYZE:
SETUP:DATA:SOURCE 2
:SEARch:I2C:ANALyze:SETup:MPOSition
Function
Sets the reference position when the analysis
reference point is set manually or queries the
current setting.
Syntax
:SEARch:I2C:ANALyze:SETup:MPOSition
{<NRf>}
:SEARch:I2C:ANALyze:SETup:
MPOSition?
<NRf>=–5 to 5 divisions (10 divisions/displayed
record length steps)
Example
:SEARCH:I2C:ANALYZE:SETUP:
MPOSITION -4.000
:SEARCH:I2C:ANALYZE:SETUP:
MPOSITION? -> :SEARCH:I2C:ANALYZE:
SETUP:MPOSITION -4.00000