3-41
IM 701450-51E
SPI Bus Signal Analysis Function
3
Command
Function
Page
:SEARch:SPI:SEARch:DATA?
Queries all settings related to the data pattern search on the analysis*
3-48
result.
:SEARch:SPI:SEARch:DATA:BYTE
Sets the number of bytes of the data pattern search on the analysis* result 3-48
or queries the current setting.
:SEARch:SPI:SEARch:DATA:HEXa<x>
Sets the pattern of the data pattern search on the analysis* result in
3-48
hexadecimal.
:SEARch:SPI:SEARch:DATA:PATTern<x>
Sets the pattern of data pattern search on the analysis* result in binary or
3-48
queries the current setting.
:SEARch:SPI:SEARch:NEXT?
Executes the search on the data after the current byte on the analysis*
3-48
result.
:SEARch:SPI:SEARch:PFORmat
Sets the pattern format of the data pattern search on the analysis* result or 3-48
queries the current setting.
:SEARch:SPI:SEARch:PREVious?
Executes the search on the data before the current byte on the analysis*
3-48
result.
:SEARch:SPI:SEARch:SOURce
Sets the data to be searched on the analysis* result or queries the current
3-48
setting.
:SEARch:SPI:SEARch:TYPE
Sets the analysis* result search type or queries the current setting.
3-49
:SEARch:TYPE
Sets the search type or queries the current setting.
3-49
SPI File Group
:FILE:SAVE:SPI:ABORt
Aborts the saving of the data of the detailed analysis list of the analysis.*
3-50
:FILE:SAVE:SPI[:EXECute]
Executes the saving of the data of the detailed analysis list of the analysis* 3-50
(overlap command).
SPI Trigger Group
:TRIGger:SPI?
Queries all settings related to the trigger.*
3-52
:TRIGger:SPI:BCOunt
Sets the trigger* byte count or queries the current setting.
3-52
:TRIGger:SPI:COMBination
Sets the combination trigger* or queries the current setting.
3-52
:TRIGger:SPI:PATTern?
Queries all settings related the pattern setting of the combination trigger.*
3-52
:TRIGger:SPI:PATTern:CHANnel<x>
Sets the condition (pattern or slope) of each channel of the combination
3-52
trigger* or queries the current setting.
:TRIGger:SPI:PATTern:CLOCk
Sets the clock channel of the combination trigger* or queries the current
3-53
setting.
:TRIGger:SPI:PATTern:CONDition
Sets the pattern condition of the combination trigger* or queries the current 3-53
setting.
:TRIGger:SPI:SETup?
Queries all settings related to the trigger.*
3-53
:TRIGger:SPI:SETup:ABCount
Sets the method of comparing Pattern B of the trigger* or queries the
3-53
current setting.
:TRIGger:SPI:SETup:APATtern?
Queries all settings related to Pattern A of the trigger* or queries the
3-53
current setting.
:TRIGger:SPI:SETup:APATtern:BYTE
Sets the number of bytes of Pattern A of the trigger* or queries the current 3-54
setting.
:TRIGger:SPI:SETup:APATtern:CONDition
Sets the Pattern A condition of the trigger* or queries the current setting.
3-54
:TRIGger:SPI:SETup:APATtern:HEXa<x>
Sets the Pattern A pattern of the trigger* at the byte level in hexadecimal.
3-54
:TRIGger:SPI:SETup:APATtern:MODE
Enables/Disables Pattern A of the trigger* or queries the current setting.
3-54
:TRIGger:SPI:SETup:APATtern:PATTern<x>
Sets the Pattern A pattern of the trigger* at the byte level in binary or
3-54
queries the current setting.
:TRIGger:SPI:SETup:BITorder
Sets the bit order of the pattern of the trigger* or queries the current setting. 3-54
:TRIGger:SPI:SETup:BPATtern?
Queries all settings related to Pattern B of the trigger* or queries the
3-54
current setting.
:TRIGger:SPI:SETup:BPATtern:BYTE
Sets the number of bytes of Pattern B of the trigger* or queries the current 3-54
setting.
:TRIGger:SPI:SETup:BPATtern:CONDition
Sets the Pattern B condition of the trigger* or queries the current setting.
3-55