![YOKOGAWA AQ2200 Series User Manual Download Page 170](http://html.mh-extra.com/html/yokogawa/aq2200-series/aq2200-series_user-manual_911202170.webp)
Item
Specifications
Error Detector Data
Receive pattern
PRBS
2n-1 (n: 7, 9, 10, 11, 15, 23, or 31)
PROGRAM
Standard: 16 to 256 bits (in 1-bit steps)
Optional: 256 to 67108864 bits (in 128-bit steps)
SDH/SONET
Optional
Descramble: Fixed to ON
Overhead: Programmable. The B1 and B2 bytes are program data.
(They are provided with no computational parity bits.)
Payload: PRBS 2n-1 (n: 9, 10, 11, 15, 23, or 31)
AUTO SYNC
ON, OFF
Measurement
function
Measurement mode
Manual: Start measurement with Measure Start, then measure until
measurement stops with Measure Stop. (If the measurement
continues for 10 days, it will be stopped automatically.)
Single: A single measurement is carried out at the user-specified time. (The
measurement stops automatically.)
Repeat: Measurements are repeatedly carried out at the user-specified
time.
Measurement time
10 days at the maximum
Measurement result
Current, 100 ms, or Last
Measurement items
Sync loss, Error count, Error rate, Overhead error count, Overhead error
rate, TX bitrate, RX bitrate, and Receive opt pwr
2
, ATT Power mon
3
Error log
Available
General Specifications
Item
Specifications
Operating conditions
The same as the frame controller’s operating environment
Temperature and humidity for storage
Ambient temperature
–10 to +50°C
Ambient humidity
20 to 80% RH (no condensation)
Dimensions and weight
Dimensions
94 (W) × 117 (H) × 321.5 (D) mm (excluding protrusions; three slots)
Weight
Approx. 2.6 kg
• All values in the specifications assume a warm-up period of one hour.
1 Specified for PPG-ED loopback measurements under the PRBS31 and data crosspoint 50% conditions.
2 Only selectable if an optical modulator module (AQ2200-621 or AQ2200-622) and an optical receiver module (AQ2200-631)
are used at the same time.
3 Only selectable if an ATTN module (AQ2200-331) is used at the same time.
5-33
IM 735101-01EN
Specifications
5.21 AQ2200-601 10 Gbit/s BERT Module
1
2
3
4
5
Index