6
-54
* 1. When C6-01 = 0, the upper limit is 150.0.
* 2. When C6-01 = 1, the upper limit is 400.0.
* 3. When C6-01 = 0, -150.0 to +150.0.
* 4. When C6-01 = 1, -400.0 to +400.0
Constants and Output Signals
Set the corresponding setting in the multi-function output (H2-01 to H2-03) to output the desired Fref/Fout
Agree signal, Fref/Set Agree signal, or Frequency Detection signal.
L4-03
Speed agree-
ment detec-
tion level (+/
-)
Effective when “Desired fre-
quency (speed) agree 2,” “Fre-
quency (FOUT) detection 3,” or
“Frequency (FOUT) detection
4" is set for a multi-function out-
put.
Frequency that should be
detected is set in Hz units.
-400.0
to
+400.0
*3
0.0 Hz
No
A
A
A
A
49BH
-300.0
to
+300.0
*4
L4-04
Speed agree-
ment detec-
tion width (+/
-)
Effective when “Frequency
(speed) agree 2,” “Desired fre-
quency (speed) agree 2,” Fre-
quency (FOUT) detection 3 or
“Frequency detection 4" is set
for a multi-function output.
Frequency detection width is set
in Hz units.
0.0 to
20.0
2.0 Hz
No
A
A
A
A
49CH
User Constant Number
Name
Function
L4-01
Speed agree detection level
Fref/Set Agree 1
Frequency Detection 1
Frequency Detection 2
L4-02
Speed agree detection width
Fref/Fout Agree 1
Fref/Set Agree 1
Frequency Detection 1
Frequency Detection 2
L4-03
Speed agree detection level (+/-)
Fref/Set Agree 2
Frequency Detection 3
Frequency Detection 4
L4-04
Speed agree detection width (+/-)
Fref/Fout Agree 2
Fref/Set Agree 2
Frequency Detection 3
Frequency Detection 4
Function
Setting
Fref/Fout Agree 1
2
Fref/Set Agree 1
3
Frequency Detection 1
4
Frequency Detection 2
5
Fref/Fout Agree 2
13
Fref/Set Agree 2
14
Frequency Detection 3
15
Frequency Detection 4
16
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
V/f
V/f
with
PG
Open
Loop
Vec-
tor
Flux
Vec-
tor