User Constant Tables
5-
47
Multi-function Contact Outputs: H2
User constants for multi-function outputs are shown in the following tables.
Multi-function Contact Output Functions
63
Field weakening command (ON: Field weakening control set for d6-01 and
d6-02)
Yes
Yes
No
No
-
64
External speed search command 3
Yes
Yes
Yes
Yes
-
65
KEB (deceleration at momentary power loss) command (NC contact)
Yes
Yes
Yes
Yes
-
66
KEB (deceleration at momentary power loss) command (NO contact)
Yes
Yes
Yes
Yes
-
67
Communications test mode (“Pass” is displayed when the communication
test is passed.)
Yes
Yes
Yes
Yes 6-106
68
High-slip braking (HSB)
Yes
Yes
No
No
-
71
Speed/torque control change (ON: Torque control)
No
No
No
Yes
6-130
6-134
72
Zero-servo command (ON: Zero-servo)
No
No
No
Yes 6-144
77
Speed control (ASR) proportional gain switch (ON: C5-03)
No
No
No
Yes 6-136
78
Polarity reversing command for external torque reference
No
No
No
Yes 6-130
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Page
V/f
V/f
with
PG
Open
Loop
Vec-
tor
Flux
Vec-
tor
H2-01
Terminal
M1-M2
function
selection
(contact)
Multi-function contact out-
put
0 to 37
0
No
A
A
A
A
40BH
-
H2-02
Terminal P1
function
selection
(open col-
lector)
Multi-function contact out-
put 1
0 to 37
1
No
A
A
A
A
40CH
-
H2-03
Terminal P2
function
selection
(open col-
lector)
Multi-function contact out-
put 2
0 to 37
2
No
A
A
A
A
40DH
-
Set-
ting
Value
Function
Control Methods
Page
V/f
V/f
with
PG
Open
Loop
Vec-
tor
Flux
Vec-
tor
0
During run (ON: Run Command is ON or voltage is being output)
Yes
Yes
Yes
Yes
6-88
1
Zero-speed
Yes
Yes
Yes
Yes
6-88
2
Frequency agree 1 (L4-02 used.)
Yes
Yes
Yes
Yes
6-54
3
Desired frequency agree 1 (ON: Output frequency = ±L4-01, L4-02 used and
during frequency agree)
Yes
Yes
Yes
Yes
6-54
Set-
ting
Value
Function
Control Methods
Page
V/f
V/f
with
PG
Open
Loop
Vec-
tor
Flux
Vec-
tor