10
-34
H1-04 Terminal S6 function selection
4 (3)
*12
H6-03 Pulse train input gain
100.0
H1-05 Terminal S7 function selection
6 (4)
*12
H6-04 Pulse train input bias
0.0
H1-06 Terminal S8 function selection
8 (6)
*12
H6-05 Pulse train input filter time
0.10
H2-01
Terminal M1-M2 function selec-
tion (contact)
0
H6-06 Pulse train monitor selection
2
H2-02
Terminal P1 function selection
(open collector)
1
H6-07 Pulse train monitor scaling
1440
H2-03
Terminal P2 function selection
(open collector)
2
L1-01 Motor protection selection
1
H3-01
Signal level selection (terminal
A1)
0
L1-02 Motor protection time constant
1.0
H3-02 Gain (terminal A1)
100.0
L1-03
Alarm operation selection during
motor overheating
3
H3-03 Bias (terminal A1)
0.0
L1-04
Motor overheating operation selec-
tion
1
H3-04
Signal level selection (terminal
A3)
0
L1-05
Motor temperature input filter time
constant
0.20
H3-05
Multi-function analog input (termi-
nal A3) function selection
1F
L2-01 Momentary power loss detection
0
H3-06 Gain (terminal A3)
100.0
L2-02
Momentary power loss ridethru
time
0.1
*6
H3-07 Bias (terminal A3)
0.0
L2-03 Min. baseblock time
0.2
*6
H3-08 Signal level selection (terminal A2)
2
L2-04 Voltage recovery time
0.3
*6
H3-09
Multi-function analog input (termi-
nal A2) function selection
0
L2-05 Undervoltage detection level
190
*9
H3-10 Gain (terminal A2)
100.0
L2-06 KEB deceleration time
0.0
H3-11 Bias (terminal A2)
0.0
L2-07 Momentary recovery time
0.0
*13
H3-12 Analog input filter time constant
0.00
L2-08
Frequency reduction gain at KEB
start
100
0.03
L3-01
Stall prevention selection during
accel
1
H3-13 Terminal A1/A2 switching
0
L3-02 Stall prevention level during accel
120
*14
H4-01 Monitor selection (terminal FM)
2
150
*14
H4-02 Gain (terminal FM)
1.00
L3-03 Stall prevention limit during accel
50
H4-03 Bias (terminal FM)
0.0
L3-04
Stall prevention selection during
decel
1
H4-04 Monitor selection (terminal AM)
3
L3-05
Stall prevention selection during
running
1
H4-05 Gain (terminal AM)
0.50
L3-06
Stall prevention level during run-
ning
120
*14
H4-06 Bias (terminal AM)
0.0
150
*14
H4-07
Analog output 1 signal level selec-
tion
0
L3-11
Overvoltage inhibit selection
0
L3-12 Overvoltage inhibit voltage level
380V
*9
H4-08
Analog output 2 signal level selec-
tion
0
L4-01 Speed agreement detection level
0.0
H5-01 Slave address
1F
L4-02 Speed agreement detection width
2.0
H5-02 Communication speed selection
3
L4-03
Speed agreement detection level
(+/-)
0.0
H5-03 Communication parity selection
0
L4-04
Speed agreement detection width
(+/-)
2.0
H5-04
Stopping method after communi-
cation error
3
L4-05
Operation when frequency refer-
ence is missing
0
H5-05
Communication error detection
selection
1
L5-01 Number of auto restart attempts
0
H5-06 Send wait time
5
L5-02 Auto restart operation selection
0
H5-07 RTS control ON/OFF
1
L6-01 Torque detection selection 1
0
H6-01 Pulse train input function selection
0
L6-02 Torque detection level 1
150
H6-02 Pulse train input scaling
1440
L6-03 Torque detection time 1
0.1
Table 10.7 User Constants (Continued)
No.
Name
Fac-
tory
Setting
Set-
ting
No.
Name
Fac-
tory
Setting
Set-
ting