User Constant Tables
5-
69
Digital Operator Constants: o
The following settings are made with the Digital Operator constants (o constants): Multi-function selections
and the copy function.
Monitor Select: o1
User constants for Digital Operator Displays are shown in the following table.
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Page
V/f
V/f
with
PG
Open
Loop
Vec-
tor
Flux
Vec-
tor
o1-01
Monitor
selection
Set the number of the moni-
tor item to be displayed in
the earliest 4 monitor items.
(U1-
)
The output monitor voltage
(factory setting) can be
changed.
4 to 99
6
Yes
A
A
A
A
500H
-
o1-02
Monitor
selection
after power
up
Sets the monitor item to be
displayed when the power is
turned on.
1: Frequency reference
2: Output frequency
3: Output current
4: The monitor item set for
o1-01
1 to 4
1
Yes
A
A
A
A
501H 6-147
o1-03
Frequency
units of ref-
erence set-
ting and
monitor
Sets the units that will be set
and displayed for the fre-
quency reference and fre-
quency monitor.
0:
0.01 Hz units
1:
0.01% units
(Maximum output
frequency is 100%)
2 to 39:
min
-1
units (Sets the motor
poles.)
40 to 39999:
User desired display
Set the desired values for
setting and display for the
max. output frequency.
Example: When the max.
output frequency value is
200.0, set 12000
0 to
39999
0
No
A
A
A
A
502H
6-147
6-164
Set 4-digit number
excluding the decimal
point.
Set the number of digits
below the decimal point
to display.