8-32
–
+
ELEC
E
CHARGING SYSTEM
CHECKING THE FUSES
8
Refer to “CHECKING THE FUSES” on
page 8-11.
CHECKING THE BATTERY
8
Refer to “CHECKING THE BATTERY”
on page 3-21.
MEASURING THE LIGHTING COIL
OUTPUT PEAK VOLTAGE
8
Measure:
• Lighting coil output peak voltage
Measure with the rectifier/regulator
output wire (red) disconnected.
Below specification
→
Replace the
lighting coil.
Lighting coil output peak voltage
Green (G) – Green (G)
r/min
Unloaded
Loaded
Unloaded
Cranking
1,500
3,500
V
9.3
7.4
37
89
Test harness (6-pin)
90890-06790
8200
G
B
R
MEASURING THE RECTIFIER/
REGULATOR OUTPUT PEAK
VOLTAGE
8
Measure:
• Rectifier/regulator output peak voltage
Below specification
→
Replace the
rectifier/regulator.
Rectifier/regulator output peak
voltage
Red (R) – Black (B)
r/min
Unloaded
Loaded
Cranking
1,500
3,500
V
—
7.5
12.5
13.0
Test harness (6-pin)
90890-06790
8200
G
B
R