Figure 85: Connections for external control source connected through comm. port
Table 14: Parameter settings for Modbus RTU and BACnet protocols
Parameter Number
Parameter Description
Protocol
Modbus RTU
BACnet
[8-02]
Control Source
FC Port
FC Port
[8-30]
Protocol
Modbus RTU
BACnet
[8-31]
Address
1
1
[8-32]
Baud Rate
19200
9600
[8-33]
Parity / Stop Bits
Even Parity, 1 Stop bit
No Parity, 1 Stop bit
[8-34]
Estimated Cycle Time
0 ms
0 ms
[8-35]
Minimum Response Delay
10 ms
10 ms
[8-36]
Maximum Response Delay
5000 ms
5000 ms
[8-37]
Maximum Inter-Char Delay
0.86 ms
25 ms
Table 15: Parameters determining control source for controller functions
Parameter number
Description
Set to
[8-01]
Control Site
Determines the location of the control source.
Set to Digital and ctrl.word to use both serial
bus and digital input control. Set to Digital
only to use only the digital inputs. Set to
Controlword only to use only the serial bus.
[8-50]
Coasting Select
Determines the control location of the coasting
(stop) function. Set to Digital input to use a
digital input only. Set to Bus to use only the
serial bus only. Set to Logic AND to use the
serial bus AND a digital input. Set to Logic OR
to use the serial bus OR a digital input.
[8-53]
Start Select
Determines the control location of the start
command. Set to Digital input to use a digital
input only. Set to Bus to use only the serial bus
only. Set to Logic AND to use the serial bus
AND a digital input. Set to Logic OR to use the
serial bus OR a digital input.
[8-55]
Set-up Select*
Determines the control location of the set-up
selection function. Set to Digital input to use a
digital input only. Set to Bus to use only the
serial bus only. Set to Logic AND to use the
serial bus AND a digital input. Set to Logic OR
to use the serial bus OR a digital input.
5 Electrical Installation
74
Aquavar
®
Intelligent Pump Controller - 150 HP to 600 HP INSTRUCTION MANUAL
Summary of Contents for Aquavar
Page 1: ...INSTRUCTION MANUAL IM273 Rev C Aquavar Intelligent Pump Controller 150 HP to 600 HP...
Page 2: ......
Page 171: ......