Frequency Converter Type Designation
3500
4000
4500
Efficiency
4)
0.98
Output frequency
0–600 Hz
0–500 Hz
Heatsink Overtemp. trip
230°F (110°C)
Power card ambient trip
140°F (60°C)
154.4°F
(68°C)
Table 41: Line power supply 525–690 V AC — Three Phase — 500 to 600 HP
Frequency Converter Type Designation
5000
6000
Typical shaft output at 550 V [kW]
400
450
Typical shaft output at 575 V [hp]
500
600
Typical shaft output at 690 V [kW]
500
560
Enclosure IP21
E1
E1
Enclosure IP54
E1
E1
Enclosure IP20/IP00
/E2
/E2
Enclosure 3R
Output current
Continuous at 550 V) [A]
523
596
Intermittent (60 sec overload) (at 550 V) [A]
575
656
Continuous (at 575/690 V) [A]
500
570
Intermittent (60 sec overload) (at 575/690 V) [A]
550
627
Continuous KVA (at 550 V) [KVA]
498
568
Continuous KVA (at 575 V) [KVA]
498
568
Continuous KVA (at 690 V) [KVA]
598
681
Maximum input current
Continuous (at 550 V) [A]
504
574
Continuous (at 575 V) [A]
482
549
Continuous (at 690 V) [A]
482
549
Maximum cable size, line power, motor, and load share [mm
2
(AWG
2
)]
4 x 240 (4 x 500 mcm)
Maximum cable size, brake [mm
2
(AWG
2
)]
2 x 185 (2 x 350 mcm)
Maximum external pre-fuses [A]
1
700
900
Estimated power loss
5)
at rated maximum load [W]
4)
, 600 V
6903
8343
Estimated power loss
5)
at rated maximum load [W]
4)
, 690 V
7249
8727
Weight, enclosure IP21, IP54 [kg]
263
272
Weight, enclosure IP00 [kg]
221
236
Efficiency
4)
0.98
Output frequency
0–500 Hz
Heatsink Overtemp. trip
230°F (110°C)
Power card ambient trip
154.4°F (68°C)
9.2 General technical data
Line powersupply
Supply terminals
L1, L2, L3
Supply voltage
380–480 V ±10%
Supply voltage
525–690 V ±10%
9 Technical Specification
Aquavar
®
Intelligent Pump Controller - 150 HP to 600 HP INSTRUCTION MANUAL
153