Bit
Hex
Dec
Alarm word
Alarm word 2 Warning word Warning word
2
Extended
Status word
Extended
Status word 2
Alarm Word Extended Status Word
10
000000400
1024
DC under Volt
(A8)
Start Failed
SC under Volt
(W8)
Multi-motor
underload
Output Freq
Low
speed < 4–52
DC Brake
11
00000080
2048
DC over Volt
(A7)
Speed Limit
SC over Volt
(W7)
Multi-motor
Overload
Brake Check
OK
brake test NOT
ok
Stop
12
00001000
4096
Short Circuit
(A16)
Pump Protect
(North
America)/
External
Interlock
(International)
DC Voltage
Low (W6)
Compress or
Interlock
Braking Max
BrakePower >
BrakePowerLi
mit (2–12)
Stand by
13
00002000
8192
Inrush Fault
(A33)
Illegal Option
Combi.
DC Voltage
High (W5)
Mechanical
Brake Sliding
Braking
Freeze Output
Request
14
00004000
16384
Input Phase
Loss (A4)
No Safety
Option
Mains ph. Loss
(W4)
Safe Option
Warning
Out of Speed
Range
Freeze Output
15
00008000
32768
AMA not OK
reserved
No Motor
(W3)
Auto DC
Braking
OVC Active
Jog Request
16
00010000
65536
Sensor Fault
(A2)
reserved
Sensor Fault
(W2)
AC Brake
Jog
17
00020000
131072
Internal Fault
(A38)
KTY error
10V Low (W1) KTY Warn
Password
Timelock
number of
allowed
password
trials
exceeded -
timelock
active
Start Request
18
00040000
262144
Brake
Overload
(A26)
Fans error
Brake
Overload
(W26)
Fans Warn
Password
Protection 0–
61 =
ALL_NO_ACCE
SS OR
BUS_NO_ACC
ESS OR
BUS_READON
LY
Start
19
00080000
524288
U phase Loss
(A30)
ECB error
Brake Resistor
(W25)
ECB Warn
Reference
High
reference > 4–
55
Start Applied
20
00100000
1048576
V phase Loss
(AA31)
reserved
Brake IGBT
(W27)
reserved
Reference Low
reference < 4–
54
Start delay
21
00200000
2097152
W phase Loss
(A32)
reserved
Speed Limit
(W49)
RESERVED
Local
Reference
reference site
= REMOTE >
auto on
pressed &
active
Sleep
7 Warnings and alarms
Aquavar
®
Intelligent Pump Controller - 150 HP to 600 HP INSTRUCTION MANUAL
137
Summary of Contents for Aquavar
Page 1: ...INSTRUCTION MANUAL IM273 Rev C Aquavar Intelligent Pump Controller 150 HP to 600 HP...
Page 2: ......
Page 171: ......