ADPRO FastTx by Xtralis
Installation and User Manual
Doc 11949_06
85
The
Quad
option captures three alarm images in a user-defined period (defined under
Camera
Settings/General
tab) and displays the images at ADPRO VideoCentral, along with a fourth
pane which sequences through the three images to highlight movement.
4.3.15 Control Outputs
The
Control Outputs
option defines a number of parameters about the type and operation of the
output circuits connected to the ADPRO FastTx. The outputs are ‘open collector’ transistor
circuits used to generate a control signal (upon activation of an alarm) to activate third-party
equipment at the remote site, for example a boom gate controller or a floodlight control device.
Select the control output number from the displayed list. The number of control outputs available
depends on the ADPRO FastTx Model number. The status of a control output is shown by a
small icon to the left of the channel number.
•
A control output is
free
when the ‘empty’ icon is shown next to the number
•
The
Connect
button is used to enable a control output. A green tick is shown and details
can be modified
•
To temporarily disable the use of a control output, the
Disconnect
button is used and a red
cross is shown. For example, set Disconnect if maintenance is being performed on the unit
under control.
Figure 85: Control Output Settings Menu