Installation and User Manual
ADPRO FastTx by Xtralis
20
Doc 11949_06
2.8.1 Powering Up the ADPRO FastTx
The green Power and the red Status LEDs on the front panel are lit as soon as power is applied
to the unit.
The ADPRO FastTx is supplied with a universal input power supply which operates from 100-
240V AC, 50-60Hz. There are no switches to change based upon your particular mains power
voltage or frequency.
If the green LED fails to illuminate check that there is power available from the socket into which
the ADPRO FastTx is connected.
The ADPRO FastTx will then automatically perform a series of self-test routines which check the
microprocessor circuits. When power is first applied to the ADPRO FastTx unit, the red LED on
the front of the unit will be on. After approximately 60 seconds, the red LED should start
switching on, then off, every two seconds. Once the unit successfully completes the integrity
check, the red LED will switch off, and remain off.
If at any time during operation, the red LED switches on and stays on, this signifies a fault with
the unit and technical support is required.
If the red LED does not switch off and remain off, do the following:
1.
Unplug all of the connectors except the power and re-power the unit.
2.
If the red LED extinguishes, plug each connector back in and check that the red LED
remains off.
3.
If the red LED does not extinguish after 10 minutes, please contact ADPRO technical
support.
If the red LED continues to flash for an extended period, this signifies that corruption has been
found with the database and the unit is attempting to correct the fault.
2.9
Connecting to the ADPRO FastTx for the First
Time
1.
Connect the PC to the ADPRO FastTx unit, via the ethernet or serial cable.
2.
Power the ADPRO FastTx up.
3.
Wait for the ADPRO FastTx to complete its start-up checks. The red status light will initially
be ON, then will start flashing, then go OFF once the checks are complete. This can take up
to two or three minutes from power on.
4.
Start ADPRO VideoCentral Lite from the icon on the desktop, if not already running.
5.
From within ADPRO VideoCentral Lite click the
Connect to Site
button.
6.
Select the site named
FastTx default site
and then select the connectors type in the
Connect Via
list. Click
OK
. You should see the Connection Status screen followed by a
screen confirming connection.