Installation and User Manual
ADPRO FastTx by Xtralis
88
Doc 11949_06
Audio Out Volume
Options:
Range 0 to 15
Factory Default:
2
Choose a volume level between 0 (lowest) and 15 (highest) to suit the operational environment.
4.3.17 Arming / Disarming
Figure 87: Arming/Disarming Menu
The Arm/Disarm properties allow a user to configure the Arm/Disarm Tamper Protection settings
and Arm/Disarm Local Indication features of ADPRO FastTx.
Alternative Arm/Disarm Input
This setting allows an unused alarm input to be configured as the access / secure (arm / disarm)
input on the ADPRO FastTx. This provides a tamper detected access / secure input as required
in the BS8418 regulations.
Whenever a tamper has occurred on the Arm/Disarm point, the ADPRO FastTx will initiate a Dial
Out and generate a tamper event. Once connected to ADPRO VideoCentral, the tamper event is
sent. This event will be identifiable as a tamper event on the Arming Device.
To configure:
Use an Alarm Input as the Arm / Disarm input
: Check this box if using this feature.
Channel
: Select an unused alarm input for the access / secure input from the drop-down list. The
alarm input will be marked as not-usable in the alarm input configuration.
Name
: Type a name for the alternative access / secure input.