ADPRO FastTx by Xtralis
Installation and User Manual
Doc 11949_06
107
To enable this option, tick the check box, then enter an appropriate time to send the reminder to
the CMS.
SitePulse
Figure 109: SitePulse Settings
SitePulse is provided as a mechanism to automatically check the operational status of a site.
SitePulse provides a mechanism where, at regular programmable intervals, a poll message is
sent from ADPRO FastTx to ADPRO VideoCentral. If ADPRO VideoCentral does not receive a
poll message from a configured site within a specified time period, this is highlighted to the
ADPRO VideoCentral operator.
Note:
Settings are required at both ADPRO FastTx and ADPRO VideoCentral to enable
SitePulse. At ADPRO VideoCentral, SitePulse must be enabled when configuring
the site (
Database
/
Administration
/
Configure Site
/
SitePulse
).
SitePulse Interval
Options:
1 min, 2 mins, 5 mins, 10 mins, 30 mins, 1 hour, 3 hours, 6 hours, 12 hours, 1
day, 2 days, 3 days, 7 days
Factory Default:
5 minutes
This option configures the time duration between SitePulse connections to ADPRO
VideoCentral.
Recommended configuration for a network SitePulse interval is relatively short, i.e. 10 or 20
minutes.
Recommended configuration for a serial modem or TA SitePulse interval is relatively long, i.e. 1
day.
ADPRO VideoCentral settings should be typically twice that of ADPRO FastTx settings, i.e. if
ADPRO FastTx SitePulse is configured for 10 minutes, then ADPRO VideoCentral should be
configured to 20 or 30 minutes.
SitePulse Start Time
This option configures the time of day to perform the SitePulse. The default time is 12pm.
When a site connection is made to ADPRO VideoCentral, either by the site calling ADPRO
VideoCentral, or via ADPRO VideoCentral calling the site, the SitePulse interval is reset. This
interval time is not restarted until the site is disconnected.