XT2640 Operating Manual
13 July 2016
Page 158 of 187
Sub
‐
Field
Sub
‐
field
Format
Value
Description
LOSS
Real power loss (in W)
EFFICIENCY or
EFF
Real power efficiency (in %)
VAR
Imaginary power (in W)
VA
Apparent power (in VA)
PF
Power factor
SPEED
Motor speed (in rpm)
SLIP
Motor slip (in %)
TORQUE
Motor torque (in Nm)
LOADZ
Load impedance (in ohms)
Measurement Source
KEYWORD
CH1, CH2, CH3 or
CH4
CH1 is DEFAULT if no other Measurement Source sub‐field found
Data is from the selected channel
A1, A2, A3, VPA1,
VPA2 or VPA3
Data is from the selected VPA
MOTOR
Data is a motor measurement result (only the Data field is used with
this, any other fields are ignored)
IN
Data is from the IN efficiency group
MIDDLE
Data is from the MIDDLE efficiency group
OUT
Data is from the OUT efficiency group
IN‐MID
Data is from the IN efficiency group to the MIDDLE efficiency group
IN‐OUT
Data is from the IN efficiency group to the OUT efficiency group
MID‐OUT
Data is from the MIDDLE efficiency group to the OUT efficiency group
2
nd
Measurement Source
(ignored if Measurement
Source is not a VPA)
KEYWORD
pA … D
Data is from the 1
st
through 4
th
(resp.) channel of the selected VPA
pAC
Data is the voltage measured between phases A and C of the selected
VPA
pAB
Data is the voltage measured between phases A and B of the selected
VPA
pBC
Data is the voltage measured between phases B and C of the selected
VPA
pN
Data is the neutral current of the selected VPA
TOTAL or
AVERAGE
DEFAULT if no other 2
nd
Measurement Source sub‐field found
Data is the total for the selected VPA, except for VOLTS and AMPS data
which is the average of all channels/phases in the selected VPA
Measurement Type
KEYWORD
DC
Data is the DC component
AC
Data is the AC component
ACDC or RMS
Data is the ACDC component
COUPLED
DEFAULT if no other Measurement Type sub‐field found
Data is the DC, AC or ACDC component as configured for the VPA
CF
Data is the crest factor (ACDC)
PK
Data is peak (ACDC)
VALLEY
Data is valley peak
PK‐VLY
Data is the difference between peak and valley peak
HIPK
Data is the highest peak (including polarity, ACDC coupled)
LOPK
Data is the lowest peak (including polarity, ACDC coupled)
THDF
Data is THD relative to fundamental amplitude (in %)
THDSIG
Data is THD relative to ACDC amplitude (in %)
H1 or H2 or H3
Data is harmonic amplitude data for the 1
st
, 2
nd
or 3
rd
harmonic
respectively
P1
Data is harmonic phase data for the fundamental (in degrees with ±180°
range)
HLIST
Data is a list of the harmonic amplitudes for each harmonic.
This may only be used with the LOGDATA command, and only with a
channel Measurement Source, and only with voltage or current
Measurement Data.
Ending Harmonic (only used if
Measurement Type is HLIST)
NR1
1 to 500
This sub‐field is only used with a Measurement Type of HLIST; if present
it is ignored for other measurement types.
Data includes harmonics up to and including this number (if this sub‐
field is not specified then the data includes all allowable harmonics, i.e.
either 100 or 500 depending on if H500 is installed)
A list of allowed combinations is provided below. In this list the following codes are used to reduce the length of the list –
CHn
Any of CH1, CH2, CH3 or CH4
An
Any of A1, A2 or A3
pX
Any of pA, pB, pC or pD
Hn
Any of H1 … 3
Not all combinations shown may be allowed in all circumstances; channels might not be installed or the configuration may not
provide valid results for a specific combination. Not all valid combinations may be shown below and where a default sub‐field value
may be used the combination is only shown without defining that specific sub‐field.
FREQ:CHn
FREQ:An
VOLTS:CHn:DC
VOLTS:CHn:AC
VOLTS:CHn:ACDC
VOLTS:CHn
VOLTS:CHn:CF
VOLTS:CHn:PK