22
W
R
220V
D
P+
C
U
V
T
S
DS5E/L-21P5-PTA, DS5E/L-22P3-PTA, DS5E/L-22P6-PTA
Terminal
Function
Explanation
R/S/T
Power supply input of
main circuit
3-phase AC 200~240V, 50/60Hz
●
Vacant terminal
-
U, V, W
Motor terminals
Connect the motor
Note: the ground wire is on the cooling
fin, please check it before power on!
P+, D, C
Internal
regenerative
resistor
Short P+ and D, disconnect P+ and C
External
regenerative
resistor
Connect regenerative resistor between P+
and C, disconnect P+ and D, P0-25=
power value, P0-26= resistor value
Ground terminal
Connect to ground terminal of motor, then
connect to the ground
W
R
380V
D
P+
C
U
V
T
S
DS5E-41P5-PTA
Terminal
Function
Explanation
R/S/T
Power supply input of
main circuit
3-phase AC 340~420V, 50/60Hz
●
Vacant terminal
-
U, V, W
Motor terminals
Connect the motor
Note: the ground wire is on the cooling
fin, please check it before power on!
P+, D, C
Internal
regenerative
resistor
Short P+ and D, disconnect P+ and C
External
regenerative
resistor
Connect regenerative resistor between P+
and C, disconnect P+ and D, P0-25=
power value, P0-26= resistor value
Power supply input of
main circuit
Connect to ground terminal of motor, then
connect to the ground
W
R
380V
U
V
T
S
P+
PB
NC
NC
P-
DS5E-45P5-PTA, DS5E-47P5-PTA
Terminal
Function
Explanation
R/S/T
Power supply input of
main circuit
3-phase AC 340~420V, 50/60Hz
NC
Vacant terminal
-
U, V, W
Motor terminals
Connect the motor
Note: the ground wire is on the cooling
fin, please check it before power on!
P+, PB
External regenerative
resistor
Connect regenerative resistor between P+
and PB, P0-25= power value, P0-26=
resistor value
P+, P-
Bus terminal
Real-time bus voltage can be measured.
Please pay attention to the danger.