64
Target speed
Rated speed
Speed up time
P3-09
Speed down
time
P3-10
5.6.4 Input signal setting
Parameter
Signal
Default
setting
Range
Modify
Effective
P5-27
Internal
direction
/SPD-D
n.0000
Range: 0000-0014. Distribute to
input terminal through P5-27.
Anytime
At once
P5-28
Internal
speed
/SPD-A
n.0000
Range: 0000-0014. Distribute to
input terminal through P5-28.
P5-29
Internal
speed
/SPD-B
n.0000
Range: 0000-0014. Distribute to
input terminal through P5-29.
(1)
Function realization
Input signal
Running speed
SPD-D
(
P5-27
)
SPD-A
(
P5-28
)
SPD-B
(
P5-29
)
0: forward run
0
0
Internal speed is zero
0
1
P3-05
:
SPEED1
1
1
P3-06
:
SPEED2
1
0
P3-07
:
SPEED3
1: reverse run
0
0
Internal speed is zero
0
1
P3-05
:
SPEED1
1
1
P3-06
:
SPEED2
1
0
P3-07
:
SPEED3
Note: The values of SPD-A and SPD-B are 1, indicating that the input level of SI terminal is valid, and
0 is invalid.