124
error
self-checking
parameters, if there are repeated
problems, please contact the
agent or manufacturer.
1
E-021
Parameter
range
beyond limit
Setting values are not
within the prescribed
range
Check parameters and reset them
2
E-022
Parameter conflict
Conflict of TREF or
VREF
Function
Settings
P0-01=4, P3-00 set to 1 will
alarm
3
E-023
Sampling channel
setting error
Error setting of custom
output trigger channel
or
data
monitoring
channel
Check that the settings are correct
4
E-024
parameter lost
Low voltage of power
grid
(1) If it is single-phase 220V
power supply, please connect L1
and L3.
(2) show E-024 immediately after
power failure
(3) Resetting parameters
5
E-025
Erase
FLASH
error
Abnormal
parameter
preservation
during
power failure
please contact the agent or the
manufacturer
6
E-026
Initialization FLASH
error
Power
supply
instability of FLASH
chip
please contact the agent or the
manufacturer
03
0
E-030
Bus voltage U0-05
is higher than the
actual
preset
threshold,
and
lasts for P0-83
setting
time
to
alarm.
220V
Power
Supply
Machine
(U0-05≥390V)
380V
Power
Supply
Machine
(U0-05≥50V)
High voltage of power
grid
Check the fluctuation of power
grid, 220V driver normal voltage
range 200V ~ 240V, 380V driver
normal voltage range 360V ~
420V. If the voltage fluctuation is
large, it is recommended to use
the correct voltage source and
regulator.
Excessive
load
moment
of
inertia
(insufficient
regeneration capacity)
(1) connect external regenerative
resistor, (220V: bus voltage
U0-05 = 380 discharge starts,
U-05 = 350 discharge ends;
380V: U-05 = 700 discharge
starts, U-05 = 660 discharge
ends;)
(2) Increasing Acceleration and
Deceleration Time
(3) Reducing load inertia
(4) Reduce start-stop frequency
(5) Replacement of larger power
drivers and motors
Brake
resistance
damage or excessive
resistance value
Check the regenerative resistor
and replace the external resistor
with the appropriate resistance
value. See chapter 1.4.1 for the
selection of the external resistor.
Acceleration
and
deceleration time is
too short
Extending
Acceleration
and
Deceleration Time
Hardware
Fault
of
Driver
Internal
Sampling Circuit
The AC gear of the multimeter
measures the input value of the
servo LN (R/S/T), which is 220V
± 10% of the normal value. If the
power supply voltage is more
than 220V+10% (380V+10%),