27
+24V
Open collector (power supply is 24V)
Relay type (power supply is 24V)
Upper device servo driver
SI
+24V
+
COM2
Y2
0
V
+24
V
R=2.2K
Ω
Upper device servo driver
R=2.2K
Ω
+24
V
0
V
Y2
COM2
+
+24V
SI
Note:
The maximum allowable voltage and current of the collector open circuit output circuit are as follows:
Voltage: DC 30V (maximum)
Current: DC 50mA (maximum)
3.2.3 SO output signal
Type
Output terminal
Function
Reference chapter
Optocoupler
output
SO1~SO3 (750W and below)
SO1~SO4 (above 1.5KW)
Multifunctional output
terminal
5.12.7
Optocoupler type
Relay type
Servo driver upper device
COM
SO
X3
COM
0
V
+24
V
Servo driver upper device
Note: The maximum load current is 400 mA (if the brake motor is controlled by SOx, please confirm
the brake current first, and if it is larger than 400 mA, please use the intermediate relay).
3.2.4 Analog input circuit
(
DS5E/5L not support
)
3.2.5 Encoder feedback output signal
(
DS5E/5L not support
)
0V
COM
X3
COM
S0