Service Parts Disassembly
Phaser 3320 and WorkCentre 3315/3325
Xerox Internal Use Only
Service Manual
4-80
Feed Actuator Spring
PL3.1.25
1.
Remove Tray 1 (page 4-5).
2.
Remove the Duplex Unit (page 4-6).
Note:
Before performing this step, note where the Feed Actuator Spring hooks into the frame.
3.
Remove 2 screws (silver, flanged, tap, 10 mm) and remove the sensor cover.
4.
Press the tab and remove the Feed Actuator.
5.
Remove the Feed Actuator Spring from the Feed Actuator.
s3320-096