Data Setup
Machine Test
Level 2
Level 3
Description
Send Level
9 to -15
Sets the level of the transmission signal. Typically, the Tx level should
be under -12 dBm.
CAUTION:
The Send Level is set at the best condition for the factory
environment. Never change settings arbitrarily.
DTMF Level
0 to 15
This sets the value of the High level tone and low level tone at DTMF
mode. (Not dial mode)
Pause Time
1 to 9
Sets the delay time when a pause is input at auto dial.
Dial Mode
Tone, Pulse
Sets the dial method: Tone, or Pulse.
Modem Speed
Dial
33.6, 28.8, 14.4,
12.0, 9.6
Sets the maximum modem speed. When communicating with a slower
modem, the modem speed is automatically set to the lower speed. It is
best set 33.6Kbps as default setting.
Error Rate
5% to 10%
When the error rate is about to exceed the set value, the Baud rate
automatically adjusts to 2400 bps. This ensures that the error rate
remains below the set value.
Clear All Mem.
This function resets the system to factory default settings. All the
information set by the user is erased.
Note:
Always perform a memory clear after replacing the Main Board,
otherwise, the system may not operate properly.
Toner Low Level
1 to 30%
Sets the amount of toner that activates the Toner Low alarm. Can be
set from 1 to 30%. Default is 10%.
Clear Counts
Enter Passcode
[????]
Resets the counter of the selected component: Fuser, Pick Up Roller,
Retard Roller, or Transfer Roller.
Engine Footer
On[Off]
This function is for monitoring the engine status. When On, the engine
footer is printed on the bottom of each printed page.
Internal Drive
Format
Yes[No]
When Yes is selected, the internal drive is formatted.
Dial Tone
On[Off]
Turns audio monitor On/Off.
Transfer Level
Level 0, Level 1,
Level 2, Level 3
Adjusts the transfer voltage to improve ghosting or blurred images.
Density Level
Level 0, Level 1,
Level 2, Level 3
Changes the density of the printed image by adjusting the bias
voltage.
Set Machine
Serial Number
XXX-xxxxxx
Sets the serial number of the machine.
Level 2
Level 3
Description
DC305 UI Test
Press any key to
start LCD test
Performs a test on the LCD.