Operation
3–14
TM-XDOP-01XN
Fold Protection options are:
•
None:
Fold protection disabled
•
CC:
Shutdown on entering CC mode
•
CV:
Shutdown on entering CV mode
•
CP:
Shutdown on entering CP mode
A programmable delay time causes the supply to wait before shutting down the
output.
To set Fold Protection:
Step # Do This
You Will See
1
OVP SET 0V
2
Press repeatedly.
Fold SD Mode
3
4
Use the arrow keys or the numeric keypad to select the
value: None, CC, CV, CP
Fold on ####
5
6
Use the arrow keys or the numeric keypad to select the
delay time.
Delay 0s
7
This setting is saved.
PROT SET
ALARMS
PROT SET
ALARMS
ENTER
ENTER
ENTER