S
C
PI C
o
mmand S
u
mmary
TM-XDOP-01XN
C
–27
Table C-11
Protection Commands
Function
SCPI Command
Description
Query
Set Over
Temperature
Response
[:]SENSe[<channel>]:TEMPerature:PROTection:LAT
Ch <on-off-state>
Select if output is latched off or
auto recovers in the case of an
over temperature condition
Yes
Query Over
Temperature
Protection Tripped
[:]SENSe[<channel>]:TEMPerature:PROTection:TRI
Pped?
Query temperature protection
tripped
N/A
Set AC Fail
Response
[:]SENSe[<channel>]:VOLTage:AC:PROTection:LATC
h <on-off-state>
Select if output is latched off or
auto recovers in the case of an AC
Fail
Yes
Query AC Fail
Protection Tripped
[:]SENSe[<channel>]:VOLTage:AC:PROTection:TRIP
ped?
Query AC protection circuit
tripped
N/A
Table C-12
User Lines
Function
SCPI Command
Description
Query
Select polarity of
Auxiliary Lines
[:]OUTPut[<channel>]:AUXiliary<A|B>:POLarity
{HIGH|LOW}
Configure the polarity of the
auxiliary line
Yes
Select Source of
Auxiliary Line State
[:]OUTPut[<channel>]:AUXiliary<A|B>:SOURce
<aux_line_mnemonic>
Configure the auxiliary line
Yes
Query state of
Auxiliary Line
[:]OUTPut[<channel>]:AUXiliary<A|B>:STATe?
Query the state of the auxiliary
line
N/A
TM-XDOP-01XN.book Page 27 Monday, July 17, 2006 11:19 AM
Summary of Contents for XDC 10-1200
Page 2: ......
Page 3: ...XDC 6000 Watt and 12000 Watt Series Digital Programmable Power Supply Operating Manual ...
Page 8: ...vi ...
Page 12: ...x ...
Page 22: ...xx ...
Page 24: ...xxii ...
Page 48: ...Installation 2 10 TM XDOP 01XN Figure 2 5 Attaching the AC Input Wires for 6000 Watt units ...
Page 114: ...Operation 3 52 TM XDOP 01XN ...
Page 208: ...A 16 ...
Page 224: ...B 16 ...
Page 259: ...D Error Messages Appendix D lists all the error codes and their meanings ...
Page 268: ...D 10 ...
Page 283: ......