GPIB Operation
TM-XDOP-01XN
4–21
SCPI
To set up GPIB control parameters:
SYST:COMM:GPIB:ADDR <GPIB-address>
where
•
the GPIB address may be in the range 1 to 30.
To configure the unit to generate a power-on service request:
SYST:COMM:GPIB:PONS {ON | OFF}
To select GPIB as the remote control source:
SYST:REM:SOUR GPIB
Using GPIB
Sending a GPIB command should put the power supply in remote mode with the
RMT
annunciator lit.
Refer to the manual for your GPIB interface card. Commands to change remote
and local mode will be specific to that card.
Press the
LCL/RMT
button to return to local mode, except if the power supply is
in
LLO
(local lockout) state.