Power Supply Operation
TM-XDOP-01XN
3–29
Configure Power ON Settings
The Power ON configuration can be set with 4 options:
•
Factory Preset:
Where the Power ON output is reset to the original factory
levels.
These include: Output=OFF, V
SET
=0, and I
SET
=0. (default configuration)
•
Last Setting:
Where the Power ON output is set to the same level as when it
was last powered OFF. This is useful for automatic recovery from short power
failures.
•
User Settings:
Where the Power ON output is set to a stored setting that is
recalled from memory. See “Store User Settings” on page 3–21.
•
Auto Sequence:
Where the Power ON output can be recalled from memory.
See “Using Auto Sequencing” on page 3–42.
The output state also depends on the Power ON Output setting. The values listed
above are true only if the OUT ON? setting is
Yes
. Otherwise Output is off (unit in
Standby mode).
See “Recall Settings” on page 3–23 for settings affected by the Power ON feature.
Each of the 4 Power ON configuration options can be accessed from the Front
Panel menus or remotely through
a set of digital commands. The procedures that
follow show how to use the Front Panel menus.
TM-XDOP-01XN.book Page 29 Monday, July 17, 2006 11:19 AM
Summary of Contents for XDC 10-1200
Page 2: ......
Page 3: ...XDC 6000 Watt and 12000 Watt Series Digital Programmable Power Supply Operating Manual ...
Page 8: ...vi ...
Page 12: ...x ...
Page 22: ...xx ...
Page 24: ...xxii ...
Page 48: ...Installation 2 10 TM XDOP 01XN Figure 2 5 Attaching the AC Input Wires for 6000 Watt units ...
Page 114: ...Operation 3 52 TM XDOP 01XN ...
Page 208: ...A 16 ...
Page 224: ...B 16 ...
Page 259: ...D Error Messages Appendix D lists all the error codes and their meanings ...
Page 268: ...D 10 ...
Page 283: ......