SCPI Commands for Digital Interfaces
TM-XDOP-01XN
4–47
REGulating Sub-Register
This describes the regulating mode. If none of these bits is active, the output
unregulated (UNRegulated) bit is active in the questionable status register.
SHUTdown Sub-Register
Describes the cause of the power supply shutting down. More than one bit may be
active, and multiple actions will be required to restart the unit. The protection
shutdown sub-register indicates which protection mechanisms have caused the
power supply to shutdown.
Table 4-10
REGulating Sub-Register
Bit
Bit Weight
Bit Name
Description
0
1
CV
The power supply is regulating in Constant Voltage mode.
1
2
CC
The power supply is regulating in Constant Current mode.
2
4
CP
The power supply is regulating in Constant Power mode.
Table 4-11
SHUTdown Sub-Register
Bit
Bit Weight
Bit Name
Description
0
1
PROTection
Summary
The power supply is shut down by a power supply protection
mechanism.
1
2
INTerlock
The power supply is shut down by INTerlock signal.
2
4
COMMand
The power supply is shut down by a command.
TM-XDOP-01XN.book Page 47 Monday, July 17, 2006 11:19 AM
Summary of Contents for XDC 10-1200
Page 2: ......
Page 3: ...XDC 6000 Watt and 12000 Watt Series Digital Programmable Power Supply Operating Manual ...
Page 8: ...vi ...
Page 12: ...x ...
Page 22: ...xx ...
Page 24: ...xxii ...
Page 48: ...Installation 2 10 TM XDOP 01XN Figure 2 5 Attaching the AC Input Wires for 6000 Watt units ...
Page 114: ...Operation 3 52 TM XDOP 01XN ...
Page 208: ...A 16 ...
Page 224: ...B 16 ...
Page 259: ...D Error Messages Appendix D lists all the error codes and their meanings ...
Page 268: ...D 10 ...
Page 283: ......