36
CleanFire Owners Manual
2016
If Boiler Is Not Heating:
1. Check fire.
2. Check pump. If pump is not running, shut off power supply to pump and inspect.
3. Check water pressure. If water is low, inspect for leaks in the system.
4. Check the ash box for ash buildup. If opening is reduced fire cannot burn properly.
5. Check the draft fan and air dampers. Make sure they are operating properly.
6. Check that the controller is not in lockout mode.
7. If water temperature is reading 120° F or lower, initiate the start process
8. Boiler cannot produce enough energy for heat demand with wood being burned. Wood or system need
to be addressed. Thermal storage may be added.
9. Check the catalyst temperature. If the catalyst is not able to maintain a temperature of 700o F or higher. then
the catalyst may be plugged or failed.
If Boiler Pressure Valve Releases:
1. Check fire chamber door. Be sure door was not left open.
2. Check fire chamber door seal. Make sure the door has a tight seal.
3. Check the draft fan and air dampers. Make sure they are operating properly.
4. In extremely warm weather, there may not be enough of a load to function properly.
In the Event of a Runaway Fire:
1. Close the door if not already closed.
2. Disconnect Power.
3. Allow the pump to continue to circulate.
4. Allow the boiler to cool. Once cool, check the boiler and heat exchanger for damage.
5. Check water pressure and level. Adjust as needed.
6. If no damage is found, power up the boiler.
7. Check the display for errors.
Troubleshooting