22
CleanFire Owners Manual
2016
Operation
When the door is open, inspect the coal bed and remove
any ash build up that may be present near the primary
air ports on each side of the fire chamber. If there is an
excess build up of ash clean the fire chamber according to
the directions in the maintenance section of this manual.
Level the coal bed if needed.
Load the fire chamber with cut, split and seasoned wood,
laying it parallel to the fire chamber sides.
Close the door completely and activate the reload function on the controller. This will purge any excess oxygen from
the boiler. Once the oxygen has been purged and the catalyst is at or above a set value, the boiler will automatically
enter burn mode. On lower heat loads, the reload function may need to be activated more than once if the catalyst
temperature is below 700F and falling.