31
CleanFire Owners Manual
2016
Maintenance
The front door should seal tightly with no visible signs of
air leakage. If a leak is detected or if the rope becomes
hard and is no longer flexible, the seal should be re-
placed.
To replace the outer door seal, locate the joint of the
rope and start to remove one end by simply pulling the
rope out of the channel on the door. Clean any debris
from the channel once the rope is removed.
Start the new rope in the same location as the old one
and press the rope into the channel on the door. Clean
the sealing surface on the boiler before closing door.
Door Seal (Daily-Yearly)
The front door as well as the rear access doors must seal properly to ensure proper combustion. The front door
seals should be inspected for damage or fatigue each time the boiler is loaded. The heat exchanger access doors
should be checked each time the heat excahnger is cleaned. The door seals are made of fiberglass rope and prop-
er personal protective equipment should be worn, including but not limited to, gloves, eye protection and long
sleeves.