7
CleanFire Owners Manual
2016
Safety
Northwest Manufacturing Inc.
600 Polk Ave SW Red Lake Falls, MN 56750 / 800-932-3629 / www.woodmaster.com
Model: CleanFire 400
Voltage: 120 V
AC
AMPS: 10
Frequency: 60 Hz
Minimum Ampactity (MCA): 10
Maximum Over Current Protective Device: 10
REFER TO OWNERS MANUAL for basic operating and maintenance instructions For Supply Connections Use 14 AWG Acceptable
for at least 105
˚
C
Replaceable circuit breaker markings are provided in the
control box for each circuit breaker.
All Flue connections must be installed with: A UL 103 listed double
wall chimney rated for solid fuel in compliance with NFPA 211.
For use on non-combustible flooring.
For Either Indoor or Outdoor Inst
allation.
Unit will not operate without electrical power.
Minimum Installation clearance: TOP: 18” (45.7 cm), FRONT: 48”(121.9 cm), SIDES: 6”(15.2 cm), REAR: 36”(91.4 cm), BOTTOM: Non-C
ombustible: 0” (0 cm)
See owner’s manual for ventilation
requirements of the heating room.
Only use cord wood as fuel as described in the owners
manual. Load fuel carefully or damage may result.
DANGER-RISK OF FIRE OR EXPLOSION
DO NOT burn garbage, gasoline, drain oil or other flammable liquids.
WARNING-RISK OF FIRE
DO NOT operate with flue draft exceeding -0.05 inch w.c.
DO NOT operate with fuel loading or ash removal doors open.
DO NOT burn garbage, gasoline, fuel oils, or other flammable liquids or materials
.
DO NOT use chemicals or fluids to start unit firing.
DO NOT store fuel or other combustible materials within marked installation clea
rances.
DO NOT connect this unit to a chimney or flue serving anot
her appliance.
Inspect and clean flues and chimney regularly.
For safety leave fuel door and ash removal doors tightly closed during operation.
In the event of a runaway fire disconnect the power supply. Allow the pump to cont
inue circulation.
The heat exchanger pipes, flue pipe, and chimney must be cleaned regularly to rem
ove accumulated creosote and ash. Ensure that the heat exchanger pipes, flue
pipe, and chimney are cleaned at the end of the heating season to minimize corros
ion during the summer months. The appliance, flue pipe and chimney must be
in good condition.
CAUTION HOT SURFACES
KEEP CHILDREN AWAY! - DO NOT TOUCH DURING OPERATION
MAXIMUM DRAFT MARKED ON NAMEPLATE
In the event of power loss, do not attempt to restart the fire without first checking for fi
re in the fire chamber, and for any damage to the unit. Check the display
for errors. If errors are present, consult with the owners manual for course of actio
n. If no fire is present, restart according to the owners manual.
PRODUCTION DATE CODE
MH29131
UL 2523 ST
AND
ARD FOR SOLID FUEL
-FIRED H
YDR
ONIC HEA
TING APPLIANCES,
W
ATER HEA
TERS, AND BOILERS - E
dition 1 - R
evision Da
te 2013/02/08
CSA B366.1-11 SOLID
-FUEL
-FIRED CENTR
AL HEA
TING APPLIANCES - E
dition 4 -
Revision Da
te 2014/01/01