9
CleanFire Owners Manual
2016
Features
1. Fire Door
2. Dry Fire Chamber
5. Negative Pressure Suction Fan
6. Isolators
7. Dampers - primary and secondary
8. Oxygen Injection Tube
9. Catalyst location
8
9
3
1
2
4
6
7
5
FEATURES
• ASME certified pressurized vessel
• Dry fire chamber
• Minimal maintenance
• Non-cycling, modulates for heat load
FUEL DOOR
• Large fuel door for ease of filling.
• Spring loaded door latch maintains pressure and
ensures a tight seal.
• Two part door, very insulated. Greatly reduces heat
transfer to the outside.
DRY FIRE CHAMBER
• Patent pending design
• A dry fire chamber means no creosote build-up, no ash
corrosion, and no need for ceramics.
• Pre-heated combustion air.
• Made from 8 gauge steel.
• Very long lasting due to no creosote.
• Extremely easy maintenance, can be cleaned in a
few minutes
COMBUSTION PROCESS
• Primary and secondary air ducts equipped with 2
dampers to allow for optimal burn.
• The remaining gasses leaving the combustion chamber
are mixed with oxygen in the injection tube ensuring a
complete combustion through the catalyst.
• The catalyst temperatures are controlled to ensure
clean combustion and longevity.
• The heat is recovered in the heat exchanger, then exits
the chimney.
• The stack averages an optimal temperature to remain
efficient, yet not condense. (approx. 240 degrees)
• The CleanFire is equipped with a lambda sensor which
monitors the oxygen levels and adjusts the boiler to
maintain the optimal burn.