1
LITTLE THURLOW MULTI-FUEL STOVE
INSTALLATION AND USER INSTRUCTIONS
Read these instructions carefully before installation and use.
These instructions should be retained by the user for future reference.
The Little Thurlow stove has a nominal heat output of 5KW and a weight of 61 kg. The flue
gas mass flow is 4.5g/s for mineral fuel and 3.7 g/s for wood logs. The mean flue gas
temperature directly downstream of the flue spigot at nominal heat output is 294 degrees C.
The stove is designed as a closed appliance and is capable of intermittent operation.
The stove must be installed to comply with Health and Safety at Work Act 1974, and to all
local Building Regulations, including those referring to National and European standards.
These need to be complied with when installing the appliance.
CO Alarms:-Building regulations require that whenever a new or replacement fixed solid
fuel or wood/biomass appliance is installed in a dwelling a carbon monoxide alarm must be
fitted in the same room as the appliance. Further guidance on the installation of the carbon
monoxide alarm is available in BS EN 50292:2002 and from the alarm manufacturer’s
instructions.
Provision of an alarm must not be considered a substitute for either installing the appliance
correctly or ensuring regular servicing and maintenance of the appliance and chimney
system.