Multifuel stove

Norm DIN EN 13240 : 2005-10

Model : 134 08 09

Output : 8 kW

Technical manual

to be saved

by the user

for future reference

FR EN NL IT

SAVOY MK2 ELEGANCE

ES

Rue Orphée Variscotte

59660 MERVILLE (FRANCE)

Telephone : 00 333 28 43 43 38

Fax : 00 333 28 43 48 60

Summary of Contents for MK2 ELEGANCE 134 08 09

Page 1: ...ertificate Document n 1274 8 20 09 2011 Multifuel stove Norm DIN EN 13240 2005 10 Model 134 08 09 Output 8 kW Technical manual to be saved by the user for future reference FR EN NL IT SAVOY MK2 ELEGANCE ES Rue Orphée Variscotte 59660 MERVILLE FRANCE Telephone 00 333 28 43 43 38 Fax 00 333 28 43 48 60 ...

Page 2: ...eant to burn wood or solid fuel safely WARNING Incorrectly installed this appliance can be dangerous and possibly cause serious accidents We recommend that you engage the services of a professional engineer for its installation and the regular maintenance requirements Door closing pressure p 6 ...

Page 3: ...ity with DIN EN 13240 2005 10 Intermittent burning heating appliance Detachable flue spigot for rear or top chimney connection Front loading door fitted with large refractory glass panel Adjustable primary air for controlling the burning rate Large ash pan 1 4 Operating principle The appliance is designed for operating only with the door closed Heat is mainly diffused by radiation through the wind...

Page 4: ...ute this load Make sure they are not combustible or covered with combustible material as per the Building regulations There must be a clearance of at least 150 mm at each side of the appliance and at the back of the appliance from a non combustible wall This measurement may be reduced to a minimum gap of 50 mm when the non combustible wall is at least 200 mm thick This distance must be extended to...

Page 5: ... combustible material walls cross members It must permit an easy sweeping 2 4 Mounting the flue collar The stove is supplied with a connection flue spigot with an inner diameter of 125 mm and an outer diameter of 139 mm The stove is set from the factory with a top outlet 2 5 Top flue outlet Figure 3 First remove the flue baffle A The stove is set from the factory with a top outlet Do not remove th...

Page 6: ...re utilisation check Check that the seals of the smoke line are in good condition Check that the door closes correctly Check that the glass is not damaged Check that the smoke passages are not obstructed by packaging or removable parts Check that all removable parts are correctly installed Note The rope seals should be checked on a regular basis as they are normal replacement parts 2 10 Maintenanc...

Page 7: ... or infirm people 3 1 Fuel This appliance is not an incinerator Use hard wood logs which have been cut for at least two years and stored under a ventilated shelter Use hardwood that have a higher calorific value per cu metre Yoke elm oak ash maple birch elm beech etc Large logs must be split and cut to an useful length before being stored in a sheltered and ventilated place Recommended fuel The be...

Page 8: ...gard to the live embers 3 5 Maintenance of the Chimney Very important In order to avoid any incident chimney fire etc maintenance tasks must be carried out regularly If the appliance is regularly used the chimney should be swept several times per year together with the stovepipe connection section If the chimney catches fire you must cut off the flue draught close the doors and windows hatches and...

Page 9: ...all wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up The flue damper is closed Open the flue damper Flue duct is cold Burn paper and kindling wood to increase heat Room is in decompression negative pressure In houses equipped with mechanical ventilation partly open a window until the fire is well established Smokes while burning Insufficient draught Open temporaril...

Page 10: ...10 Technical manual 1274 SAVOY MK2 model 134 08 09 Note Note ...

Page 11: ...236138 Reducing plate A B C D 01 23 237406 Reducing plate A B C D 01 24 237427 Reducing plate A B C D 01 25 259015 Fixing plate A B C D 04 26 262607 Heat shield A B C D 01 27 270402 Air control flap A B C D 01 29 300128 EF Leg A 04 29 300128 RH Leg B 04 29 300128 RP Leg C 04 29 300128 MK Leg D 04 30 300446 EF Base A 01 30 300446 RH Base B 01 30 300446 RP Base C 01 30 300446 MK Base D 01 31 301526 ...

Page 12: ...Technical manual 1274 SAVOY MK2 model 134 08 09 Spare parts Figure 8 Spare parts view 20 50 21 7 51 51 6 0 52 ...

Page 13: ...1 42 327910 MK Tray D 01 43 331132 EF Main door A 01 43 331132 RH Main door B 01 43 331132 RP Main door C 01 43 331132 MK Main door D 01 44 332004 Air duct A B C D 01 45 352176 EF Top plate A 01 45 352176 RH Top plate B 01 45 352176 RP Top plate C 01 45 352176 MK Top plate D 01 46 406816 Clamp A B C D 01 47 415504 60 Poker A B C D 01 48 624042 Ash pan A B C D 01 49 808001 ED Hand tool A B C D 01 N...

Page 14: ...the exception of closed combustion fireplace and inserts for which our guarantee is 5 five years excluding the following 1 Indicator lights fuses electrical elements and fans 2 Parts subject to wear or in contact with high temperatures namely soles and burner grills bottom plates baffles ash pans paintwork and surface treatments for decorative parts Also excluded from this guarantee are seals and ...