73
3.1.10 LLDP
This page allows the user to inspect and configure the current LLDP interface settings.
LLDP Parameters
Tx Interval
The switch periodically transmits LLDP frames to its neighbors for having the network discovery information
up-to-date. The interval between each LLDP frame is determined by the
Tx Interval
value. Valid values are
restricted to 5 - 32768 seconds.
Tx Hold
Each LLDP frame contains information about how long time the information in the LLDP frame shall be
considered valid. The LLDP information valid period is set to
Tx Hold
multiplied by
Tx Interval
seconds. Valid
values are restricted to 2 - 10 times.
Tx Delay
If some configuration is changed (e.g. the IP address) a new LLDP frame is transmitted, but the time between
the LLDP frames will always be at least the value of
Tx Delay
seconds.
Tx Delay
cannot be larger than 1/4 of
the
Tx Interval
value. Valid values are restricted to 1 - 8192 seconds.
Tx Reinit
When a interface is disabled, LLDP is disabled or the switch is rebooted, a LLDP shutdown frame is transmitted
to the neighboring units, signaling that the LLDP information isn't valid anymore.
Tx Reinit
controls the amount
of seconds between the shutdown frame and a new LLDP initialization. Valid values are restricted to 1 - 10
seconds.
LLDP Interface Configuration
Interface
The switch interface name of the logical LLDP interface.
Mode