151
3.3.2 TRACEROUTE (IPv4)
This page allows you to perform a
traceroute
test over IPv4 towards a remote host.
traceroute
is a diagnostic tool
for displaying the route and measuring transit delays of packets across an IPv4 network.
You can configure the following parameters for the test:
Hostname or IP Address
The destination IP Address.
DSCP Value
This value is used for the DSCP value in the IPv4 header. The default value is 0. The valid range is 0-63.
Number of Probes Per Hop
Determines the number of probes (packets) sent for each hop. The default value is 3. The valid range is 1-60.
Response Timeout
Determines the number of seconds to wait for a reply to a sent request. The default number is 3. The valid
range is 1-86400.
First TTL Value
Determines the value of the Time-To-Live (TTL) field in the IPv4 header in the first packet sent. The default
number is 1. The valid range is 1-30.
Max TTL Value
Determines the maximum value of the Time-To-Live (TTL) field in the IPv4 header. If this value is reached
before the specified remote host is reached the test stops. The default number is 30. The valid range is
1-255.
VID for Source Interface
This field can be used to force the test to use a specific local VLAN interface as the source interface. Leave
this field empty for automatic selection based on routing configuration.
Note: You may only specify either the VID or the IP Address for the source interface.
Address for Source Interface
This field can be used to force the test to use a specific local interface with the specified IP address as the
source interface. The specified IP address must be configured on a local interface. Leave this field empty for