152
automatic selection based on routing configuration.
Note: You may only specify either the VID or the IP Address for the source interface.
Use ICMP instead of UDP
By default the
traceroute
command will use UDP datagrams. Selecting this option forces it to use ICMP
ECHO packets instead.
Print Numeric Addresses
By default the
traceroute
command will print out hop information using a reverse DNS lookup for the
acquired host ip addresses. This may slow down the display if the DNS information is not available. Selecting
this option will prevent the reverse DNS lookup and force the
traceroute
command to print numeric IP
addresses instead.
Traceroute (IPv6)
This page allows you to perform a
traceroute
test over IPv6 towards a remote host.
traceroute
is a diagnostic tool
for displaying the route and measuring transit delays of packets across an IPv6 network.
You can configure the following parameters for the test:
Hostname or IP Address
The destination IP Address.
DSCP Value
This value is used for the DSCP value in the IPv4 header. The default value is 0. The valid range is 0-255.
Number of Probes Per Hop
Determines the number of probes (packets) sent for each hop. The default value is 3. The valid range is 1-60.
Response Timeout
Determines the number of seconds to wait for a reply to a sent request. The default number is 3. The valid
range is 1-86400.
Max TTL Value
Determines the maximum value of the Time-To-Live (TTL) field in the IPv4 header. If this value is reached
before the specified remote host is reached the test stops. The default number is 255. The valid range is
1-255.
VID for Source Interface
This field can be used to force the test to use a specific local VLAN interface as the source interface. Leave
this field empty for automatic selection based on routing configuration.
Note: You may only specify either the VID or the IP Address for the source interface.
Address for Source Interface
This field can be used to force the test to use a specific local interface with the specified IP address as the
source interface. The specified IP address must be configured on a local interface. Leave this field empty for
automatic selection based on routing configuration.
Note: You may only specify either the VID or the IP Address for the source interface.
Print Numeric Addresses