www.wobit.com.pl
User manual SID116 – 09.04.2015r. v.1.0 page 22
Picture. 20. I/O configuration window
Parts of I/O configuration window:
1 – Number of driver input
2 – Signals assigned to input, signals on input can be connected on base logical disjunction (by one input can be
triggerded several signals)
3 – Input logical state
4 – Virtual input – enforcing current input state:
ON – enforcing input active state
OFF –enforcing not active
5 – Input polarity:
HIGH – high state on driver input corresponds to active signal
LOW – low state on driver input corresponds to active signal
6 – Configuration of signals assigned to input
7 – Number of driver output
8 – Signals assigned to output
9 – Output logical state
10- Virtual output, enforcing current output state:
ON – enforcing output active state
OFF – enforcing not active
11 – Output polarity:
HIGH – active signal state corresponds to high state on output
LOW – active signal state corresponds to low state on output
12 – Configuration of signals assigned to output