Serial inputs – control using digital inputs with value counted to setting
index (individual input activates directly ascribed index).
Modbus/PC – control by PC application or Modbus RTU protocol by setting
index selection.
Interface tab presents current value of selected interface.
Analog input field – presents current voltage at driver analog input in miliwolts (mV)
Analog input field presents current value of analog input converted by Interface
coefficients.
Master encoder value field – displays value of master encoder converted by Interface
coefficients. Next to this field is located a reset button.
Step/Dir field – displays value of step/dir interface converted by Interface coefficients.
Next to this field is located a reset button.
AB pulse field – displays value of pulse interface converted by Interface coefficients.
Next to this field is located a reset button.
Interface coefficients – is conversion of interface value by linear function. There are
available two conversion modes:
Gain/Constant coefficient mode – means direct entering of coeffincients
Minimum/Maximum mode – means giving value which will be indicated for
0 and for 10 000 value.
Gain field allows to enter control interface amplification (floating point value). Entered
value should be confirmed by pressing ENTER button.
Constant coefficient field allows to enter constant coefficient of control interface
(floating point value). Entered value should be confirmed by pressing ENTER button.
Minimum field allows to enter control interface value (floating point value) at 0 point.
Entered value should be confirmed by pressing ENTER button.
Maksimum field allows to enter control interface value (floating point value) at 10 000
point. Entered value should be confirmed by pressing ENTER button.
I/O tab displays inputs state and allows to control its state.
Inputs buttons 0.0 – 0.7, 1.0 – 1.2 – displays status of proper driver inputs. Pressing of
the button cause enforcing inputs high state. Enforcing settings are saved to non-
violate memory and allows to activate input while driver start-up.
Q0 – Q4 buttons – displays status of proper driver outputs. Pressing of the button
cause enforcing outputs high state. Enforcing settings are saved to non-violate
memory and allows to activate output while driver start-up.
Signal fields allows to display values of selected signals.
Parallel inputs field indicates index inidcated by index inputs at parallel mode.
Binary inputs field indicates by index inputs at binary mode.
4.2.2
Advanced settings.