5.
Driver configuration
5.1
Commissioning
CAUTION!
While commissioning please follow rules included at this chapter and please respect order of
mentioned actions.
5.1.1
Software update.
Before commissioning it is recommended to download the latest software from
At catalogue with software is placed SID116–PC application used for driver configuration and current version of
driver firmware with FirmwareUpdater.exe program for its update.
Before commissioning please update firmware according to manual included in catalogue.
5.1.2
Driver commissioning step by step.
I
Please connect driver power supply, then connect driver to PC using USB cable. Other I/O leave not
connected. At first connection to computer drivers of operational system will install automatically. Please
wait until its finish.
II
Start SID116 – PC application.
III
Read in default settings (1) and save settings (2). After record driver will restart which will be signalized by
LED diode blinking on front panel.
IV
Go to advanced settings tab to configure drive parameters:
Enter resolution of encoder mounted on motor shaft. Resolution is given without considering square
wave signal. If encoder is not included leave this value without changes.
Enter motor rated current in mA
Enter rated velocity if drive uses encoder
Enter motor rated voltage in mV
Enter voltage supply in mV
While commissioning can be entered lower value of rated current e.g. 10-25% of rated value. It
allows to limit motor torque.
CAUTION!
Entered power supply source voltage can’t be lower than existing maximal voltage supplied by
power supply source. Wrong entering of parameter can damage the driver!
V
Set driver to operation at open loop. Pleas select „Open loop” sheet (1). Then press „Activate mode” (2).
Settings can be edited by pressing selected setting and change its value at form located on the right
(3).